I-间碘苄胍 SPECT 心脏显像对心力衰竭患者预后价值的系统评价。

The prognostic value of I-mIBG SPECT cardiac imaging in heart failure patients: a systematic review.

机构信息

Department of Radiological Sciences, Oncology and Anatomical Pathology, Sapienza University of Rome, Viale Regina Elena 324, 00161, Rome, Italy.

Department of Public Health and Infectious Diseases, "Sapienza" University of Rome, Rome, Italy.

出版信息

J Nucl Cardiol. 2022 Aug;29(4):1799-1809. doi: 10.1007/s12350-020-02501-w. Epub 2021 Jan 13.


DOI:10.1007/s12350-020-02501-w
PMID:33442819
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC9345809/
Abstract

This systematic review aimed to evaluate the prognostic value of Iodine123 Metaiodobenzylguanidine (I-mIBG) SPECT myocardial imaging in patients with heart failure (HF) and to assess whether semi-quantitative SPECT scores can be useful for accurate risk stratification concerning arrhythmic event (AE) and sudden cardiac death (SCD) in this cohort. A systematic literature search of studies published until November 2020 regarding the application of I-mIBG SPECT in HF patients was performed, in Pubmed, Scopus, Medline, Central (Cochrane Library) and Web Of Science databases, including the words "MIBG", "metaiodobenzylguanidine", "heart", "spect", and "tomographic". The included studies had to correlate I-mIBG SPECT scores with endpoints such as overall survival and prevention of AE and SCD in HF patients. According to the sixteen studies included, the analysis showed that 123I-mIBG SPECT scores, such as summed defect score (SDS), regional wash-out (rWO), and regional myocardial tracer uptake, could have a reliable prognostic value in patients with HF. An increased SDS or rWO, as well as a reduced I-mIBG myocardial uptake, have proven to be effective in predicting AE- and SCD-specific risk in HF patients. Despite achieved results being promising, a more reproducible standardized method for semi-quantitative analysis and further studies with larger cohort are needed for I-mIBG SPECT myocardial imaging to be as reliable and, thus, accepted as the conventional I-mIBG planar myocardial imaging.

摘要

本系统评价旨在评估碘-123 间碘苄胍(I-mIBG)单光子发射计算机断层扫描(SPECT)心肌显像在心力衰竭(HF)患者中的预后价值,并评估半定量 SPECT 评分是否可用于对该患者队列中的心律失常事件(AE)和心脏性猝死(SCD)进行准确的危险分层。在 Pubmed、Scopus、Medline、Cochrane 图书馆和 Web Of Science 数据库中,对截至 2020 年 11 月发表的关于 I-mIBG SPECT 在 HF 患者中应用的研究进行了系统文献检索,使用了“MIBG”、“metaiodobenzylguanidine”、“heart”、“spect”和“tomographic”等词。纳入的研究必须将 I-mIBG SPECT 评分与终点相关联,如 HF 患者的总生存率以及 AE 和 SCD 的预防。根据纳入的十六项研究,分析表明,123I-mIBG SPECT 评分,如总和缺损评分(SDS)、区域性洗脱(rWO)和区域性心肌示踪剂摄取,在 HF 患者中可能具有可靠的预后价值。增加的 SDS 或 rWO 以及减少的 I-mIBG 心肌摄取已被证明可有效预测 HF 患者的 AE 和 SCD 特异性风险。尽管取得的结果很有前景,但需要更可重复的半定量分析标准化方法和更大规模队列的进一步研究,以使 I-mIBG SPECT 心肌成像更可靠,从而像传统的 I-mIBG 平面心肌成像一样被接受。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/38b5/9345809/fa12b1a2b039/12350_2020_2501_Fig3_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/38b5/9345809/ab94ae6ea536/12350_2020_2501_Fig1_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/38b5/9345809/16afeb47e1c9/12350_2020_2501_Fig2_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/38b5/9345809/fa12b1a2b039/12350_2020_2501_Fig3_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/38b5/9345809/ab94ae6ea536/12350_2020_2501_Fig1_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/38b5/9345809/16afeb47e1c9/12350_2020_2501_Fig2_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/38b5/9345809/fa12b1a2b039/12350_2020_2501_Fig3_HTML.jpg

相似文献

[1]
The prognostic value of I-mIBG SPECT cardiac imaging in heart failure patients: a systematic review.

J Nucl Cardiol. 2022-8

[2]
Feasibility of the absolute quantification and left ventricular segmentation of cardiac sympathetic innervation in wild-type transthyretin amyloidosis cardiomyopathy with [I]-MIBG SPECT/CT: The I-NERVE study.

J Nucl Cardiol. 2025-3

[3]
Cost-effectiveness of using prognostic information to select women with breast cancer for adjuvant systemic therapy.

Health Technol Assess. 2006-9

[4]
Impact of residual disease as a prognostic factor for survival in women with advanced epithelial ovarian cancer after primary surgery.

Cochrane Database Syst Rev. 2022-9-26

[5]
Systematic review of the effectiveness and cost-effectiveness, and economic evaluation, of myocardial perfusion scintigraphy for the diagnosis and management of angina and myocardial infarction.

Health Technol Assess. 2004-7

[6]
Transfusion thresholds for guiding red blood cell transfusion.

Cochrane Database Syst Rev. 2021-12-21

[7]
Semi-quantitative MIBG scores in relapsed/refractory neuroblastoma: Prognostic insights from post-131I-MIBG treatment scans and impact of SPECT-CT imaging.

Rev Esp Med Nucl Imagen Mol (Engl Ed). 2025-6-20

[8]
The clinical and cost-effectiveness of left ventricular assist devices for end-stage heart failure: a systematic review and economic evaluation.

Health Technol Assess. 2005-11

[9]
Systemic treatments for metastatic cutaneous melanoma.

Cochrane Database Syst Rev. 2018-2-6

[10]
EORTC guidelines for the use of erythropoietic proteins in anaemic patients with cancer: 2006 update.

Eur J Cancer. 2007-1

引用本文的文献

[1]
Exploring Cardiac Sympathetic Denervation in Transthyretin-Mediated Hereditary Amyloidosis (ATTRv): Insights from I-mIBG Scintigraphy.

Diagnostics (Basel). 2025-2-19

[2]
Intranasal Radioiodinated Ferulic Acid Polymeric Micelles as the First Nuclear Medicine Imaging Probe for ETRA Brain Receptor.

Curr Radiopharm. 2024

[3]
The sympathetic nervous system in heart failure revisited.

Heart Fail Rev. 2024-3

[4]
Thyroid [I]MIBG uptake in Parkinson's disease and diabetes mellitus.

IBRO Neurosci Rep. 2023-3-21

[5]
Performance evaluation of a novel multi-pinhole collimator on triple-NaI-detector SPECT/CT for dedicated myocardial imaging.

EJNMMI Phys. 2023-3-25

[6]
Rationalizing the Binding Modes of PET Radiotracers Targeting the Norepinephrine Transporter.

Pharmaceutics. 2023-2-17

[7]
Application of I-MIBG myocardial maximum standardized uptake value to characterize cardiac function in patients with pheochromocytoma: comparison with echocardiography.

Jpn J Radiol. 2023-4

[8]
I-MIBG imaging in heart failure: impact of comorbidities on cardiac sympathetic innervation.

Eur J Nucl Med Mol Imaging. 2023-2

[9]
Cardiovascular/Stroke Risk Stratification in Parkinson's Disease Patients Using Atherosclerosis Pathway and Artificial Intelligence Paradigm: A Systematic Review.

Metabolites. 2022-3-31

[10]
Cardiac I-mIBG scintigraphy for prediction of catheter ablation outcome in patients with atrial fibrillation.

J Nucl Cardiol. 2022-10

本文引用的文献

[1]
Prediction of appropriate ICD therapy in patients with ischemic heart failure.

J Nucl Cardiol. 2022-4

[2]
Cardiac Imaging With I-meta-iodobenzylguanidine and Analogous PET Tracers: Current Status and Future Perspectives.

Semin Nucl Med. 2020-7

[3]
Left-ventricular innervation assessed by I-SPECT/CT is associated with cardiac events in inherited arrhythmia syndromes.

Int J Cardiol. 2020-8-1

[4]
The utility of heart-to-mediastinum ratio using a planar image created from IQ-SPECT with Iodine-123 meta-iodobenzylguanidine.

J Nucl Cardiol. 2021-12

[5]
Regional Cardiac Sympathetic Nervous System Evaluation Using 123I-mIBG SPECT in Patients with Heart Failure.

J Med Imaging Radiat Sci. 2018-12

[6]
Cardiac innervation imaging as a risk stratification tool for potential device therapy candidates.

J Nucl Cardiol. 2020-10

[7]
Iodine-123-metaiodobenzylguanidine cardiac SPECT imaging in the qualification of heart failure patients for ICD implantation.

J Nucl Cardiol. 2019-8

[8]
Role of cardiac I-mIBG imaging in predicting arrhythmic events in stable chronic heart failure patients with an ICD.

J Nucl Cardiol. 2018-3-28

[9]
Early therapeutic effects of adaptive servo-ventilation on cardiac sympathetic nervous function in patients with heart failure evaluated using a combination of C-HED PET and I-MIBG SPECT.

J Nucl Cardiol. 2017-11-27

[10]
Cardiac I-mIBG scintigraphy is associated with freedom of appropriate ICD therapy in stable chronic heart failure patients.

Int J Cardiol. 2017-8-25

文献AI研究员