Abstract

OBJECTIVE

To prepare monoclonal antibody against cotinine (COT) and to establish immunoassay for detecting COT in human urinary samples.

METHODS

BALB/c mice were immunized with synthesized cotinine-bovine serum albumin (COT-BSA) to screen monoclonal antibody with technique of cell fusion. The monoclonal antibody was used for the indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) and colloidal gold immunochromatographic strip assay for the detection of COT in human urine.

RESULTS

The monoclonal antibody against COT was identified by ic-ELISA with a 50%inhibitive concentration (IC) value of 21 ng/mL; and it was also identified by colloidal gold immunochromatographic strip assay with a cut-off value of 100 ng/mL. For ic-ELISA, the range of detection was 0-100 ng/mL with a minimal limit of 0.1 ng/mL; the recovery of assay was 99.41%-117.98%, and the intra-assay and inter-assay coefficient variations were not higher than 15.31%and 15.07%, respectively. For colloidal gold immunochromatographic strip assay, the accuracy of stability and repeatability both were 100%.

CONCLUSIONS

The ic-ELISA and colloidal gold immunochromatographic strip assay using the prepared monoclonal antibody against COT have been proved to be reliable for the rapid detection of COT in human urines, which may be used for monitoring of environmental tobacco smoke.

摘要

目的

制备抗可替宁(COT)单克隆抗体并建立检测人尿液中COT的免疫分析方法。

方法

用合成的可替宁 - 牛血清白蛋白(COT - BSA)免疫BALB/c小鼠,采用细胞融合技术筛选单克隆抗体。该单克隆抗体用于间接竞争酶联免疫吸附测定(ic - ELISA)和胶体金免疫层析试纸条法检测人尿液中的COT。

结果

通过ic - ELISA鉴定抗COT单克隆抗体,其50%抑制浓度(IC)值为21 ng/mL;通过胶体金免疫层析试纸条法鉴定,其临界值为100 ng/mL。对于ic - ELISA,检测范围为0 - 100 ng/mL,最低检测限为0.1 ng/mL;测定回收率为99.41% - 117.98%,批内和批间变异系数分别不高于15.31%和15.07%。对于胶体金免疫层析试纸条法,稳定性和重复性的准确率均为100%。

结论

使用制备的抗COT单克隆抗体的ic - ELISA和胶体金免疫层析试纸条法已被证明可可靠地快速检测人尿液中的COT,可用于监测环境烟草烟雾。

相似文献

本文引用的文献

4
The millennium development goals and tobacco control.千年发展目标与烟草控制。
Glob Health Promot. 2010 Mar;17(1 Suppl):51-9. doi: 10.1177/1757975909358250.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验