A protein conjugate of streptomycin (streptomycin-bovine serum albumin (BSA) conjugate) was prepared and used as immunogen to produce monoclonal antibodies (MAb). One hybridoma secreting anti-streptomycin MAb was obtained and then used to produce MAb. The MAb named 13H5 showed the 50% maximal inhibitory concentration (IC(50)) value of 4.65 ng/ml and the IC(20) value of 0.21 ng/ml in phosphate buffered saline (PBS). At optimum conditions, an indirect competitive enzyme-linked immunosorbent assay (ELISA) and a colloidal gold-based immunochromatographic assay (CGIA) were developed and applied to detect streptomycin residues in milk and swine urine samples. The developed ELISA showed that the minimum detection limit was 2.0 and 1.9 ng/ml for milk and swine urine samples, respectively, without obvious cross-reactivity to other tested antibiotics except dihydrostreptomycin which gave a 118.32% cross reaction value. Milk and swine urine samples spiked with streptomycin at 10, 50, 100 and 200 ng/ml were analyzed by the established ELISA. The mean recovery of streptomycin was from 81.9% to 105.5% and from 84.3% to 92.2% for milk and swine urine, respectively. The optimized CGIA showed that the minimum detection limit was 20.0 ng/ml for milk and swine urine samples. The results of spiked analysis and specific analysis demonstrate that the CGIA could be applicable for screening milk and swine urine samples for the presence of streptomycin residues on-site. The established ELISA and CGIA allow the rapid, low-cost, and sensitive determination of streptomycin residues in food samples.
制备了链霉素蛋白结合物(链霉素-牛血清白蛋白(BSA)结合物),并将其用作免疫原以产生单克隆抗体(MAb)。获得了分泌抗链霉素 MAb 的杂交瘤细胞,并随后用于产生 MAb。该 MAb 命名为 13H5,在磷酸盐缓冲盐水(PBS)中显示出 50%最大抑制浓度(IC(50))值为 4.65ng/ml,IC(20)值为 0.21ng/ml。在最佳条件下,开发并应用间接竞争酶联免疫吸附测定(ELISA)和胶体金免疫层析测定(CGIA)来检测牛奶和猪尿液样品中的链霉素残留。开发的 ELISA 表明,牛奶和猪尿液样品的最低检测限分别为 2.0 和 1.9ng/ml,除二氢链霉素外,对其他测试的抗生素没有明显的交叉反应,二氢链霉素的交叉反应值为 118.32%。用建立的 ELISA 分析了在牛奶和猪尿液中添加 10、50、100 和 200ng/ml 链霉素的样品。链霉素的平均回收率分别为牛奶 81.9%至 105.5%,猪尿液 84.3%至 92.2%。优化的 CGIA 表明,牛奶和猪尿液样品的最低检测限分别为 20.0ng/ml。加标分析和特异性分析的结果表明,CGIA 可用于现场筛选牛奶和猪尿液样品中是否存在链霉素残留。建立的 ELISA 和 CGIA 允许快速、低成本、灵敏地测定食品样品中的链霉素残留。