健康年轻男性腘绳肌的电抗肌图测试-重测信度。

Test-retest reliability of electrical impedance myography in hamstrings of healthy young men.

机构信息

Sports Department, Pará State University, Belém, Brazil; Northeast Biotechnology Network, Postgraduate Program in Biotechnology, Ceará State University, Fortaleza, Brazil.

Biotechnology and Exercise Biology Research Laboratory, Institute of Physical Education and Sports, Federal University of Ceará, Fortaleza, Brazil.

出版信息

J Electromyogr Kinesiol. 2021 Feb;56:102511. doi: 10.1016/j.jelekin.2020.102511. Epub 2021 Jan 7.

Abstract

Several techniques are available to assess muscle tissue status, including electrical impedance myography (EIM). Despite being used in the assessment of neuromuscular status in injury and response to exercise, reliability data for hamstrings muscles are limited. Therefore, this study aimed to determine the test-retest reliability of EIM components on hamstrings. Twenty-one healthy males (25.3 ± 3.4 years; 173 ± 6.7 cm; and 79.7 ± 15.9 kg) volunteered for this study. Subjects completed two visits, separated by seven days to collect EIM components (resistance, reactance, impedance, and phase angle) in the longitudinal and transversal axis of hamstrings in both thighs, using a bioimpedance device and Ag/AgCL adhesive contact electrodes. The electrode arrangement was in the muscular belly, half the distance between origin and insertion of the hamstrings. Reliability was determined by the intraclass correlation coefficient (ICC), minimal detectable change (MDC), and Bland-Altman plots. We observed high to excellent reliability (ICC > 0.85) between all EIM components, except for reactance with MDC ranged from 2.0 to 10.8 and the mean bias in Bland-Altman plots ranged from -0.02 to 2.48 (95% limits of agreement from -9.98 to 11.20). From our findings, the hamstrings assessment using EIM technique is reliable to assess muscle tissue; therefore, it enables the evaluation of changes/adaptations in clinical and applied contexts.

摘要

有几种技术可用于评估肌肉组织状态,包括电阻抗肌描记法(EIM)。尽管 EIM 已被用于评估损伤和运动反应中的神经肌肉状态,但有关腘绳肌的可靠性数据有限。因此,本研究旨在确定 EIM 组件在评估腘绳肌时的测试-再测试可靠性。21 名健康男性(25.3±3.4 岁;173±6.7cm;79.7±15.9kg)自愿参加了这项研究。受试者在 7 天的间隔内完成了两次访问,以使用生物阻抗设备和 Ag/AgCL 粘性接触电极分别在两个大腿的纵向和横向轴上收集腘绳肌的 EIM 组件(电阻、电抗、阻抗和相位角)。电极排列在肌肉腹部,距离腘绳肌起点和止点的一半距离。可靠性通过组内相关系数(ICC)、最小可检测变化(MDC)和 Bland-Altman 图来确定。我们观察到所有 EIM 组件之间的可靠性都很高(ICC>0.85),除了电抗的 MDC 范围为 2.0 到 10.8,Bland-Altman 图中的平均偏差范围为-0.02 到 2.48(95%一致性界限为-9.98 到 11.20)。根据我们的发现,使用 EIM 技术评估腘绳肌具有可靠性,可用于评估肌肉组织的变化/适应,因此它可以在临床和应用环境中进行评估。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验