采用呼吸运动引导 4D CBCT 最小化 4D CBCT 成像剂量和扫描时间:一项临床前研究。

Minimizing 4DCBCT imaging dose and scan time with Respiratory Motion Guided 4DCBCT: a pre-clinical investigation.

机构信息

ACRF Image X Institute, Faculty of Medicine and Health, The University of Sydney, Australia.

出版信息

Biomed Phys Eng Express. 2021 Jan 28;7(2). doi: 10.1088/2057-1976/abdc82.

Abstract

Current conventional 4D Cone Beam Computed Tomography (4DCBCT) imaging is hampered by inconsistent patient breathing that leads to long scan times, reduced image quality and high imaging dose. To address these limitations, Respiratory Motion Guided 4D cone beam computed tomography (RMG-4DCBCT) uses mathematical optimization to adapt the gantry rotation speed and projection acquisition rate in real-time in response to changes in the patient's breathing rate. Here, RMG-4DCBCT is implemented on an Elekta Synergy linear accelerator to determine the minimum achievable imaging dose. 8 patient-measured breathing traces were programmed into a 1D motion stage supporting a 3D-printed anthropomorphic thorax phantom. The respiratory phase and current gantry position were calculated in real-time with the RMG-4DCBCT software, which in turn modulated the gantry rotation speed and suppressed projection acquisition. Specifically, the effect of acquiring 20, 25, 30, 35 and 40 projections/respiratory phase bin RMG scans on scan time and image quality was assessed. Reconstructed image quality was assessed via the contrast-to-noise ratio (CNR) and the Edge Response Width (ERW) metrics. The performance of the system in terms of gantry control accuracy was also assessed via an analysis of the angular separation between adjacent projections. The median CNR increased linearly from 5.90 (20 projections/bin) to 8.39 (40 projections/bin). The ERW did not significantly change from 1.08 mm (20 projections/bin) to 1.07 mm (40 projections/bin), indicating the sharpness is not dependent on the total number of projections acquired. Scan times increased with increasing total projections and slower breathing rates. Across all 40 RMG-4DCBCT scans performed, the average difference in the acquired and desired angular separation between projections was 0.64°. RMG-4DCBCT provides the opportunity to enable fast low-dose 4DCBCT (∼70 s, 200 projections), without compromising on current clinical image quality.

摘要

当前的传统 4D 锥形束计算机断层扫描(4DCBCT)成像受到患者呼吸不一致的限制,导致扫描时间长、图像质量降低和成像剂量高。为了解决这些限制,呼吸运动引导 4D 锥形束计算机断层扫描(RMG-4DCBCT)使用数学优化来实时适应旋转架旋转速度和投影采集率,以响应患者呼吸率的变化。在这里,RMG-4DCBCT 是在 Elekta Synergy 直线加速器上实现的,以确定可达到的最小成像剂量。将 8 个患者测量的呼吸轨迹编程到一个支持 3D 打印人体胸腔模型的 1D 运动台上。RMG-4DCBCT 软件实时计算呼吸相位和当前旋转架位置,从而调节旋转架旋转速度并抑制投影采集。具体来说,评估了在 RMG 扫描中采集 20、25、30、35 和 40 个投影/呼吸相位 bin 的效果,以评估扫描时间和图像质量。通过对比度噪声比(CNR)和边缘响应宽度(ERW)指标评估重建图像质量。还通过分析相邻投影之间的角度分离来评估系统在旋转架控制精度方面的性能。CNR 的中位数从 5.90(20 个投影/ bin)线性增加到 8.39(40 个投影/ bin)。ERW 从 1.08 毫米(20 个投影/ bin)到 1.07 毫米(40 个投影/ bin)没有显著变化,表明锐度不依赖于采集的总投影数。扫描时间随总投影数的增加和呼吸频率的降低而增加。在执行的所有 40 次 RMG-4DCBCT 扫描中,投影之间实际和期望角度分离的平均差异为 0.64°。RMG-4DCBCT 提供了实现快速低剂量 4DCBCT(约 70 s,200 个投影)的机会,而不会影响当前的临床图像质量。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验