Suppr超能文献

年龄相关呼吸特征对用于放射治疗计划的前瞻性门控重建的四维磁共振成像性能的影响。

Effects of age-related breathing characteristics on the performance of four-dimensional magnetic resonance imaging reconstructed by prospective gating for radiation therapy planning.

作者信息

Uh Jinsoo, Kadbi Mo, Hua Chia-Ho

机构信息

Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA.

Philips Healthcare, Gainesville, FL, USA.

出版信息

Phys Imaging Radiat Oncol. 2019 Sep 23;11:82-87. doi: 10.1016/j.phro.2019.09.004. eCollection 2019 Jul.

Abstract

BACKGROUND AND PURPOSE

Four-dimensional magnetic resonance imaging (4D MRI) has advanced recently by incorporating prospective gating, but its performance on pediatric populations has not been investigated. This study aimed to determine the age-related performance of prospective gating, as compared with retrospective sorting.

MATERIALS AND METHODS

Prospectively gated 4D MRI scans were acquired on a motion phantom driven by real respiratory waveforms obtained from 23 pediatric and young adult patients (aged 5-24 years). The correlations between patient-specific breathing characteristics and the performance of 4D MRI were comparatively evaluated against retrospective sorting for the same scan time. For six patients who underwent both 4D MRI and 4D CT, the internal target volumes (ITVs) determined by the two modalities were compared.

RESULTS

Longer scan time and greater sorting error were most highly correlated ( < 0.001) with breathing irregularity and extent of diaphragm motion, but age was not a strong covariate because of interindividual variation. Prospective gating was more accurate than retrospective sorting except for those patients with severe breathing irregularity (peak-to-peak coefficient of variation >30%). The ITVs of 4D MRI and 4D CT were comparable (Dice similarity: >90%) unless the breathing characteristics changed between the two imaging sessions.

CONCLUSIONS

For most patients analyzed in this study, prospective gating provided more accurate 4D MRI (95th percentile of deviation: <1.5 mm) than did retrospective sorting within a clinically feasible scan time (median: 5.9 min). The 4D MRI tended to take longer and to give larger sorting errors with deeper and irregular breathers.

摘要

背景与目的

四维磁共振成像(4D MRI)最近通过纳入前瞻性门控技术取得了进展,但其在儿科人群中的性能尚未得到研究。本研究旨在确定与回顾性分类相比,前瞻性门控技术与年龄相关的性能。

材料与方法

对由23名儿科和年轻成人患者(年龄5 - 24岁)的真实呼吸波形驱动的运动模型进行前瞻性门控4D MRI扫描。针对相同扫描时间,比较评估患者特定呼吸特征与4D MRI性能之间的相关性,并与回顾性分类进行对比。对6名同时接受4D MRI和4D CT检查的患者,比较两种检查方式确定的内部靶体积(ITV)。

结果

较长的扫描时间和较大的分类误差与呼吸不规则性和膈肌运动程度高度相关(<0.001),但由于个体差异,年龄不是一个强协变量。除了那些呼吸严重不规则(峰 - 峰值变异系数>30%)的患者外,前瞻性门控比回顾性分类更准确。除非两次成像检查之间呼吸特征发生变化,4D MRI和4D CT的ITV具有可比性(骰子相似性:>90%)。

结论

对于本研究中分析的大多数患者,在前瞻性门控在临床可行的扫描时间(中位数:5.9分钟)内,比回顾性分类提供了更准确的4D MRI(偏差的第95百分位数:<1.5毫米)。对于呼吸较深且不规则的患者,4D MRI往往需要更长的时间且分类误差更大。