OBJECTIVE

Evaluate the feasibility and potential impacts on hand function using a wearable stimulation device (the VTS Glove) which provides mechanical, vibratory input to the affected limb of chronic stroke survivors.

METHODS

A double-blind, randomized, controlled feasibility study including sixteen chronic stroke survivors (mean age: 54; 1-13 years post-stroke) with diminished movement and tactile perception in their affected hand. Participants were given a wearable device to take home and asked to wear it for three hours daily over eight weeks. The device intervention was either (1) the VTS Glove, which provided vibrotactile stimulation to the hand, or (2) an identical glove with vibration disabled. Participants were randomly assigned to each condition. Hand and arm function were measured weekly at home and in local physical therapy clinics.

RESULTS

Participants using the VTS Glove showed significantly improved Semmes-Weinstein monofilament exam results, reduction in Modified Ashworth measures in the fingers, and some increased voluntary finger flexion, elbow and shoulder range of motion.

CONCLUSIONS

Vibrotactile stimulation applied to the disabled limb may impact tactile perception, tone and spasticity, and voluntary range of motion. Wearable devices allow extended application and study of stimulation methods outside of a clinical setting.

摘要

目的

评估一种可穿戴刺激设备(VTS 手套)对手功能的可行性和潜在影响,该设备向慢性卒中幸存者患侧肢体提供机械振动输入。

方法

一项双盲、随机、对照可行性研究纳入了 16 名慢性卒中幸存者(平均年龄:54 岁;卒中后 1-13 年),他们的患手运动和触觉感知能力下降。参与者被给予一个可穿戴设备带回家,并要求在八周内每天佩戴三个小时。设备干预措施为(1)VTS 手套,对手部提供振动触觉刺激,或(2)具有振动功能禁用的相同手套。参与者被随机分配到每个条件。每周在家中和当地物理治疗诊所测量手部和手臂功能。

结果

使用 VTS 手套的参与者的 Semmes-Weinstein 单丝检查结果明显改善,手指的改良 Ashworth 测量值降低,以及一些自愿手指弯曲、肘部和肩部活动范围增加。

结论

向失能肢体施加振动触觉刺激可能会影响触觉感知、张力和痉挛以及主动运动范围。可穿戴设备允许在临床环境之外扩展刺激方法的应用和研究。