Rodriguez Z, Caixeta L S, Cramer G
Department of Veterinary Population Medicine, University of Minnesota, Saint Paul, MN, United States.
Vet Anim Sci. 2020 Dec 14;11:100159. doi: 10.1016/j.vas.2020.100159. eCollection 2021 Mar.
This study aims to evaluate the diagnostic accuracy of the bovine specific beta-hydroxybutyrate () meter Nova Vet (). We evaluated the accuracy and agreement of the NVET in fresh blood and thawed serum with the reference laboratory assay; and the repeatability, the interference by anticoagulants, and the optimum slope calibration factor. Individual blood samples were collected from 200 Holstein and crossbred cows between 3 and 14 days post-calving from 13 dairy herds in Minnesota. Using a laboratory assay with a cut point of 1.2 BHB mmol/L hyperketonemia prevalence was 10.6% (95% CI: 6.7, 15.8). The sensitivity of NVET in blood and serum was 100.0% while the specificity was 98.3 and 97.7% respectively. The agreement between NVET and the laboratory assay was the highest using blood samples (concordance correlation coefficient -CCC = 96.2, 95% CI: 95.0, 97.1. The coefficient of variation including within day (intra-meter), between- days, and -batches was 13.4% when testing blood samples. Minimal interference was observed with the use of anticoagulants (K-EDTA and Li-Heparin, CCC 0.90 and 0.93 respectively) in reference to whole blood without anticoagulant. The best calibration slope factor in serum was 1.0 (Youden's index: 0.98). Results suggest that the NVET device maintained a high accuracy and precision to quantified BHB concentration when applied in fresh blood and thawed serum under field conditions using the default calibration slope (1.0), and with minimal anticoagulant interference when used in whole blood samples.
本研究旨在评估牛专用β-羟丁酸()检测仪Nova Vet()的诊断准确性。我们评估了Nova Vet在新鲜血液和解冻血清中相对于参考实验室检测方法的准确性和一致性;以及其重复性、抗凝剂的干扰作用和最佳斜率校准因子。从明尼苏达州13个奶牛场的200头荷斯坦奶牛和杂交奶牛产后3至14天采集个体血样。采用切点为1.2 BHB mmol/L的实验室检测方法,高酮血症患病率为10.6%(95%CI:6.7,15.8)。Nova Vet在血液和血清中的敏感性为100.0%,而特异性分别为98.3%和97.7%。使用血样时,Nova Vet与实验室检测方法之间的一致性最高(一致性相关系数-CCC = 96.2,95%CI:95.0,97.1)。检测血样时,包括日内(仪器内)、日间和批次间的变异系数为13.4%。与未抗凝的全血相比,使用抗凝剂(K-EDTA和Li-肝素,CCC分别为0.90和0.93)时观察到的干扰最小。血清中的最佳校准斜率因子为1.0(约登指数:0.98)。结果表明,在现场条件下,使用默认校准斜率(1.0),将Nova Vet设备应用于新鲜血液和解冻血清中时,其对BHB浓度的定量具有较高的准确性和精密度,并且在全血样本中使用时抗凝剂干扰最小。