Suppr超能文献

应用右心室流入道和流出道同步图像测量胎儿右改良心肌做功指数的新方法及其在双胎输血综合征中的临床应用。

Novel Technique for the Measurement of Fetal Right Modified Myocardial Performance Index Using Synchronized Images of Right Ventricular Inflow and Outflow and Clinical Application to Twin-to-Twin Transfusion Syndrome.

机构信息

Department of Obstetrics and Gynecology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.

R&D Lab/Samsung Medison Co., Ltd., Seoul, Korea.

出版信息

J Ultrasound Med. 2021 Nov;40(11):2467-2475. doi: 10.1002/jum.15634. Epub 2021 Jan 25.

Abstract

OBJECTIVE

To evaluate the reproducibility of the fetal right modified myocardial performance index (Mod-MPI) obtained by synchronizing the inflow and outflow images of the right ventricle (RV) and to evaluate its feasibility through clinical application to twin-to-twin transfusion syndrome (TTTS).

METHODS

We prospectively evaluated 77 normal fetuses. Two experienced operators individually measured the right Mod-MPI using two different methods: (1) separate recording of the RV inflow and outflow using pulsed-wave Doppler (conventional method) and (2) synchronization of RV inflow and outflow images using the MPI + ™ function based on the closure click of the pulmonary valve (new method). To evaluate the clinical utility of the new method, we measured the right Mod-MPI in 33 TTTS fetuses using the new method before and after the fetoscopic laser coagulation (FLC).

RESULTS

There was no statistical difference in Mod-MPI values between the two methods (p = .242). For both operators, the intra- and interoperator reproducibility of Mod-MPI was high with both methods (ICCs >0.950). Among the components of Mod-MPI measured using the new method, ejection time showed the highest reproducibility, whereas isovolumetric relaxation time demonstrated the lowest reproducibility. In TTTS fetuses, the Mod-MPI significantly decreased after FLC in recipients, and there was no difference in MPI values before and after FLC in donors.

CONCLUSION

Right Mod-MPI measurement after the synchronization of RV inflow and outflow images is a reliable technique for evaluating fetal right cardiac function. This novel method can also independently evaluate the systolic and diastolic functions of the right heart.

摘要

目的

评估通过同步右心室(RV)流入和流出图像获得的胎儿右改良心肌性能指数(Mod-MPI)的可重复性,并通过对双胎输血综合征(TTTS)的临床应用评估其可行性。

方法

我们前瞻性评估了 77 例正常胎儿。两名有经验的操作者分别使用两种不同的方法测量右 Mod-MPI:(1)使用脉冲波多普勒(常规方法)分别记录 RV 流入和流出,(2)使用基于肺动脉瓣关闭点击的 MPI + ™功能同步 RV 流入和流出图像(新方法)。为了评估新方法的临床实用性,我们使用新方法测量了 33 例 TTTS 胎儿在胎儿镜激光凝固(FLC)前后的右 Mod-MPI。

结果

两种方法的 Mod-MPI 值无统计学差异(p =.242)。对于两名操作者,两种方法的 Mod-MPI 均具有很高的内-间操作者可重复性(ICC >0.950)。在使用新方法测量的 Mod-MPI 各组成部分中,射血时间的可重复性最高,等容舒张时间的可重复性最低。在 TTTS 胎儿中,受者 FLC 后 Mod-MPI 显著降低,供者 FLC 前后 MPI 值无差异。

结论

RV 流入和流出图像同步后的右 Mod-MPI 测量是评估胎儿右心功能的可靠技术。这种新方法还可以独立评估右心的收缩和舒张功能。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验