Suppr超能文献

超薄Descemet膜剥除自动内皮角膜移植术(UT-DSAEK)与Descemet膜内皮角膜移植术(DMEK)的视觉质量和主观满意度:同眼比较

Visual Quality and Subjective Satisfaction in Ultrathin Descemet Stripping Automated Endothelial Keratoplasty (UT-DSAEK) versus Descemet Membrane Endothelial Keratoplasty (DMEK): A Fellow-Eye Comparison.

作者信息

Torras-Sanvicens Josep, Blanco-Domínguez Irene, Sánchez-González José-María, Rachwani-Anil Rahul, Spencer Juan-Felipe, Sabater-Cruz Noelia, Peraza-Nieves Jorge, Rocha-de-Lossada Carlos

机构信息

Anterior Segment Department, Institut Clinic d'Oftalmologia, Hospital Clinic of Barcelona, 08036 Barcelona, Spain.

Ophthalmology Department, University of Barcelona, 08007 Barcelona, Spain.

出版信息

J Clin Med. 2021 Jan 22;10(3):419. doi: 10.3390/jcm10030419.

Abstract

BACKGROUND

To analyze objective and subjective visual quality differences between descemet membrane endothelial keratoplasty (DMEK) and ultra-thin descemet stripping automated endothelial keratoplasty (UT-DSAEK) with a paired contralateral-eye design.

METHODS

A cross-sectional, comparative, and observational case series study between DMEK and UT-DSAEK were presented. Visual acuity, refractive status and corneal quality assessment were compared between both endothelial keratoplasty techniques. The sample consisted of 20 eyes (10 patients) diagnosed with Fuchs endothelial corneal dystrophy. All measurements were performed preoperatively and at six months after surgery. Analyzed data included the measurement of objective scattering index, modulation transfer function, Strehl ratio, and optical quality assessment (OQAS) values. Contrast sensitivity, subjective patient satisfaction, visual acuity, tomography, pachymetry, endothelial cell count, and refraction status were also analyzed.

RESULTS

Objective and subjective visual quality variables had similar results among UT-DSAEK and DMEK procedures. Statistically significant differences favoring DMEK against UT-DSAEK were found in endothelial cell density (658.80 ± 139.33 and 1059.00 ± 421.84 cells/mm, respectively), pachymetry (621.20 ± 33.74 and 529.70 ± 30.00 µm, respectively), and follow-up (45.50 ± 24.76 and 15.50 ± 8.43 months, respectively).

CONCLUSIONS

UT-DSAEK and DMEK revealed no differences in terms of objective and subjective visual quality. However, DMEK showed a faster recovery during the follow-up, increased endothelial cell density, lower pachymetry, and a more anatomical posterior keratometry against UT-DSAEK in this case series paired-eye study.

摘要

背景

采用配对对侧眼设计分析深板层内皮角膜移植术(DMEK)与超薄Descemet膜剥除自动内皮角膜移植术(UT-DSAEK)之间客观和主观视觉质量的差异。

方法

呈现了一项DMEK与UT-DSAEK之间的横断面、比较性观察病例系列研究。比较了两种内皮角膜移植技术之间的视力、屈光状态和角膜质量评估。样本包括20只眼睛(10例患者),均诊断为Fuchs内皮角膜营养不良。所有测量均在术前和术后6个月进行。分析的数据包括客观散射指数、调制传递函数、斯特列尔比和光学质量评估(OQAS)值的测量。还分析了对比敏感度、患者主观满意度、视力、断层扫描、角膜厚度测量、内皮细胞计数和屈光状态。

结果

UT-DSAEK和DMEK手术的客观和主观视觉质量变量结果相似。在内皮细胞密度(分别为658.80±139.33和1059.00±421.84个细胞/mm)、角膜厚度测量(分别为621.20±33.74和529.70±30.00µm)以及随访时间(分别为45.50±24.76和15.50±8.43个月)方面,发现DMEK相对于UT-DSAEK有统计学显著差异。

结论

UT-DSAEK和DMEK在客观和主观视觉质量方面没有差异。然而,在本配对眼病例系列研究中,DMEK在随访期间恢复更快,内皮细胞密度增加,角膜厚度更低,并且相对于UT-DSAEK,后表面角膜曲率更符合解剖结构。

相似文献

引用本文的文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验