In this study, a gold labelled immunochromatographic assay was developed to detect tigecycline (TGC) in human serum. For this purpose, an anti-TGC monoclonal antibody, 2G7, was produced and characterized, and was found to have a 50%-inhibitory concentration (IC50) of 2.303 ng mL-1 and a limit of detection (LOD) of 0.215 ng mL-1 for TGC. This strip assay had a visual limit of detection (vLOD) of 50 ng mL-1 and a cut-off value of 1000 ng mL-1 for TGC in human serum, when assessed by eye. With the aid of a strip scan reader, a quantitative determination of TGC was obtained with a calculated limit of detection (cLOD) of 15.03 ng mL-1. Analysis of TGC in human serum indicated that the results of our strip assay compared well with results obtained using ic-ELISA and LC-MS/MS. Therefore, this strip assay represents a sensitive and reliable method for the on-site detection of TGC in serum samples.

摘要

在本研究中,开发了一种金标免疫层析法用于检测人血清中的替加环素(TGC)。为此,制备并表征了一种抗TGC单克隆抗体2G7,发现其对TGC的50%抑制浓度(IC50)为2.303 ng/mL,检测限(LOD)为0.215 ng/mL。当通过肉眼评估时,该条带分析法对人血清中TGC的视觉检测限(vLOD)为50 ng/mL,临界值为1000 ng/mL。借助条带扫描读数器,获得了TGC的定量测定结果,计算检测限(cLOD)为15.03 ng/mL。人血清中TGC的分析表明,我们的条带分析法结果与免疫竞争酶联免疫吸附测定法(ic-ELISA)和液相色谱-串联质谱法(LC-MS/MS)获得的结果相当。因此,该条带分析法是一种用于血清样品中TGC现场检测的灵敏且可靠的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验