Suppr超能文献

椎基底动脉系统的形态学指标具有遗传性吗?一项基于三维重建模型的双胞胎研究。

Are the Morphological Indices of the Vertebrobasilar System Heritable? A Twin Study Based on 3D Reconstructed Models.

作者信息

Szalontai Laszlo, Jokkel Zsofia, Horvath Tamas, Piroska Marton, Forgo Bianka, Olah Csaba, Kostyal Laszlo, Tarnoki David L, Tarnoki Adam D

机构信息

Medical Imaging Centre, Semmelweis University, 78/A Üllői Street, 1082 Budapest, Hungary.

Oncologic Imaging Diagnostic Center, Department of Radiology, National Institute of Oncology, Ráth György Street 7-9, 1122 Budapest, Hungary.

出版信息

Medicina (Kaunas). 2021 Feb 1;57(2):127. doi: 10.3390/medicina57020127.

Abstract

: The asymmetrical vertebral artery (VA) flow and diameter are common findings, which can result in an asymmetrical blood flow in the basilar artery (BA), leading to bending of the artery over time. This study investigated whether the variation of the different vertebrobasilar morphological indices that influence flow characteristics might be inherited. We analyzed 200 cerebral magnetic resonance imaging (MRI) scans of healthy Caucasian twins (100 pairs) who underwent time-of-flight MRI. From the scans, we reconstructed the 3D mesh of the posterior circulation from the start of the V4 segment to the basilar tip and subsequently analyzed the morphology of the vertebrobasilar system. The phenotypic covariances of the different morphological parameters were decomposed into heritability (A), shared (C), and unshared (E) environmental effects. 39% of the twins had left dominant VA, while 32.5% had right dominant. In addition, 28.5% were classified as equal. The vertebral artery V4 segment diameter, curvature, and tortuosity were mainly influenced by shared (C) and unshared (E) environmental factors. A moderate heritability was found for the BA length (A: 63%; 95% CI: 45.7-75.2%; E: 37%; 95% CI: 24.8-54.3%) and volume (A: 60.1%; 95% CI: 42.4-73.2%; E: 39.9%; 95% CI: 26.8-57.6%), while the torsion of both arteries showed no heritability and were only influenced by the unshared environment. The length and volume of the BA show a moderate genetical influence. However, most of the measured morphological indices were influenced by shared and unshared factors, which highlight the role of the ever-changing hemodynamic influences shaping the geometry of the vertebrobasilar system.

摘要

椎动脉(VA)血流和直径不对称是常见现象,这会导致基底动脉(BA)血流不对称,随着时间推移导致动脉弯曲。本研究调查了影响血流特征的不同椎基底形态学指标的变异是否可能具有遗传性。我们分析了200例接受时间飞跃磁共振成像(MRI)的健康白种人双胞胎(100对)的脑磁共振成像扫描。通过扫描,我们从V4段起始处到基底动脉尖端重建了后循环的三维网格,随后分析了椎基底系统的形态。不同形态学参数的表型协方差被分解为遗传度(A)、共享(C)和非共享(E)环境效应。39%的双胞胎椎动脉左侧优势,而32.5%为右侧优势。此外,28.5%被归类为相等。椎动脉V4段直径、曲率和扭曲主要受共享(C)和非共享(E)环境因素影响。发现基底动脉长度(A:63%;95%置信区间:45.7 - 75.2%;E:37%;95%置信区间:24.8 - 54.3%)和体积(A:60.1%;95%置信区间:42.4 - 73.2%;E:39.9%;95%置信区间:26.8 - 57.6%)有中度遗传度,而两条动脉的扭转无遗传度,仅受非共享环境影响。基底动脉的长度和体积显示出中度遗传影响。然而,大多数测量的形态学指标受共享和非共享因素影响,这突出了不断变化的血流动力学影响在塑造椎基底系统几何形状中的作用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4d9b/7912720/335da5805079/medicina-57-00127-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验