Abstract

OBJECTIVE

To evaluate imaging quality (IQ) and International Federation of Gynecology and Obstetrics (FIGO) staging of reduced field-of-view (r-FOV) diffusion-weighted imaging (DWI) in cervical carcinoma (CC).

MATERIALS AND METHODS

Sixty patients with pathologically proven CC who underwent both pre-treatment r-FOV DWI and full field-of-view (f-FOV) DWI on a 3.0T MRI scanner were retrospectively reviewed. The subjective qualitative image scores were compared using the Wilcoxon signed-rank test. Objective quality values and apparent diffusion coefficient (ADC) were estimated by paired t-test or Wilcoxon signed-rank test for the two DWI sequences according to Normality test. Spearman rank correlation analysis was used to evaluate the relationship between pathological results and mean ADC value.

RESULTS

The subjective IQ scores for r-FOV DWI were significantly higher than those for f-FOV DWI (P < 0.001). Similarly, the contrast-to-noise (CNR) value of r-FOV DWI was superior to that of f-FOV DWI (10.30 ± 3.676, 8.91 ± 3.008, P = 0.021). However, the signal-to-noise ratio (SNR) value of r-FOV DWI was considerably lower than that of f-FOV DWI (27.80 ± 6.056, 33.67 ± 7.833, P<0.001). No significant difference was found between mean ADC values of f-FOV DWI and r-FOV DWI. There was a significant tendency for a negative correlation between the ADC values and FIGO stages of CC for both two sequences (r=-0. 436, P<0.01; r=-0.470, P<0.01, respectively).

CONCLUSIONS

The rFOV DWI sequence provided significantly better IQ and lesion conspicuity than the fFOV DWI sequence. In addition, rFOV sequences can be used in evaluation of FIGO staging of cervical cancer.

摘要

目的

评估宫颈癌(CC)小视野(r-FOV)弥散加权成像(DWI)的成像质量(IQ)和国际妇产科联合会(FIGO)分期。

材料与方法

回顾性分析 60 例经病理证实的 CC 患者,这些患者在 3.0T MRI 扫描仪上分别进行了治疗前 r-FOV DWI 和全视野(f-FOV)DWI。使用 Wilcoxon 符号秩检验比较主观定性图像评分。根据正态性检验,对两种 DWI 序列的客观质量值和表观扩散系数(ADC)进行配对 t 检验或 Wilcoxon 符号秩检验。采用 Spearman 秩相关分析评估病理结果与平均 ADC 值之间的关系。

结果

r-FOV DWI 的主观 IQ 评分明显高于 f-FOV DWI(P<0.001)。同样,r-FOV DWI 的对比噪声比(CNR)值也优于 f-FOV DWI(10.30±3.676,8.91±3.008,P=0.021)。然而,r-FOV DWI 的信噪比(SNR)值明显低于 f-FOV DWI(27.80±6.056,33.67±7.833,P<0.001)。f-FOV DWI 和 r-FOV DWI 的平均 ADC 值之间无显著差异。两种序列的 ADC 值与 CC 的 FIGO 分期之间均呈显著负相关趋势(r=-0.436,P<0.01;r=-0.470,P<0.01)。

结论

rFOV DWI 序列在 IQ 和病灶显著性方面明显优于 fFOV DWI 序列。此外,rFOV 序列可用于评估宫颈癌的 FIGO 分期。