Orthopedics and Trauma Department, SS Annunziata Hospital, Savigliano (CN), Italy.
SS Annunziata Hospital Savigliano (CN).
Acta Biomed. 2020 Dec 30;91(14-S):e2020002. doi: 10.23750/abm.v91i14-S.10598.
Conical coupling represents an alternative to screw coupling on angular stable plate fixation. Aims of the present study was to evaluate clinical effectiveness and ease of plate removal of conical coupling locking plates into different scenario regarding quality of bone, type of fracture and operative technique.
From May 2013 to December 2017, 198 patients with 206 fractures underwent open reduction and internal fixation with conical locking plate. In most cases fixation involved wrist (38%) and clavicle (24%) fractures but a varied type of fractures and bone were included in the study.
Ten complications related to plate fixation were observed (5,1%). Two case of intra-articular positioning of screws of wrist plate. One case of loss of reduction and breakage of wrist plate due to an inappropriate proximal fracture fixation. Five cases of complications involved clavicle fixation: three cases of non-union, one case of peri-implant fracture, one screw loosening. One non-union of distal tibial fracture, one non-union in olecranon fracture were finally observed. Thirty-four patients that have symptoms that could be traceable to the implants in-situ underwent plate removal. No complications were observed during surgical plates removal. Conical coupling angular stability plate represents an actractive alternative to threaded angular stability plate. Bush titanium insert, eliminating the problems of cold welding and cross-threading, simplifies surgical screws and plate removal.
在角稳定钢板固定中,锥形接头是螺丝接头的替代方案。本研究的目的是评估锥形接头锁定板在不同骨质量、骨折类型和手术技术情况下的临床效果和易于取出。
2013 年 5 月至 2017 年 12 月,198 例 206 例骨折患者采用锥形锁定板行切开复位内固定。大多数固定涉及腕关节(38%)和锁骨(24%)骨折,但也包括各种类型的骨折和骨骼。
观察到与钢板固定相关的 10 种并发症(5.1%)。腕关节钢板螺钉关节内定位 2 例。1 例因近端骨折固定不当导致复位丢失和腕关节钢板断裂。锁骨固定并发症 5 例:3 例不愈合,1 例植入物周围骨折,1 例螺钉松动。1 例胫骨远端骨折不愈合,1 例鹰嘴骨折不愈合。34 例有症状可追溯至原位植入物的患者行钢板取出术。手术取出钢板时无并发症。锥形接头角稳定板是螺纹角稳定板的一种有吸引力的替代方案。钛制 Bush 插入物消除了冷焊和螺纹交叉的问题,简化了手术用螺钉和钢板的取出。