Exp Biol Med (Maywood). 2021 May;246(10):1210-1218. doi: 10.1177/1535370221991147. Epub 2021 Feb 16.
Whole-body vibration (WBV), which is widely used as a type of exercise, involves the use of vibratory stimuli and it is used for rehabilitation and sports performance programmes. This study aimed to investigate the effect of WBV treatment in a chronic pain model after 10 WBV sessions. An animal model (chronic pain) was applied in 60 male Wistar rats (±180 g, 12 weeks old) and the animals were treated with low intensity exercise (treadmill), WBV (vibrating platform), and a combined treatment involving both. The controls on the platform were set to a frequency of 42 Hz with 2 mm peak-to-peak displacement, g ≈ 7, in a spiral mode. Before and after the vibration exposure, sensitivity was determined. Aβ-fibers-mediated mechanical sensitivity thresholds (touch-pressure) were measured using a pressure meter. C-fibers-mediated thermal perception thresholds (hot pain) were measured with a hot plate. After each session, WBV influenced the discharge of skin touch-pressure receptors, reducing mechanical sensitivity in the WBV groups ( < 0.05). Comparing the conditions "before vs. after", thermal perception thresholds (hot pain) started to decrease significantly after the third WBV session ( < 0.05). WBV decreases mechanical hyperalgesia after all sessions and thermal sensitivity after the third session with the use of WBV.
全身振动(WBV)作为一种运动方式被广泛应用,涉及使用振动刺激,用于康复和运动表现计划。本研究旨在调查 10 次 WBV 治疗后慢性疼痛模型中的治疗效果。在 60 只雄性 Wistar 大鼠(±180g,12 周龄)中应用动物模型(慢性疼痛),对动物进行低强度运动(跑步机)、WBV(振动平台)和同时进行两种治疗。平台上的对照频率设置为 42Hz,峰值到峰值位移为 2mm,g≈7,呈螺旋模式。在振动暴露前后,测定敏感性。使用压力计测量 Aβ纤维介导的机械敏感性阈值(触压)。使用热板测量 C 纤维介导的热感觉阈值(热痛)。每次治疗后,WBV 都会影响皮肤触压感受器的放电,降低 WBV 组的机械敏感性(<0.05)。比较“治疗前 vs. 治疗后”,热感觉阈值(热痛)在第三次 WBV 治疗后开始显著降低(<0.05)。使用 WBV 治疗后,WBV 会降低所有治疗后的机械性痛觉过敏和第三次治疗后的热敏感性。