BACKGROUND Acute kidney injury with acute renal failure is associated with severe diabetic ketoacidosis. This retrospective study was conducted at a single center in China and aimed to compare combined hemodialysis and hemoperfusion (hemodialysis+hemoperfusion) with hemoperfusion alone in 106 patients with diabetic ketoacidosis and acute renal failure. MATERIAL AND METHODS The 106 patients were divided into 2 groups according to different dialysis programs, with 53 cases in each group. Hemodialysis was performed using a single-pass 4008S FX8 HeLix-One hollow fiber hemodialyzer (Fresenius Medical Care, St. Wendel, Germany). Hemoperfusion was performed using HA130 resin adsorbents. RESULTS There were no significant differences in terms of sex, age, duration of diabetes, A1c, pH, and admission blood glucose between the 2 groups (P=0.54, 0.564, 0.53, 0.78, 0.82, 0.51). There were no significant differences in fasting blood glucose, blood urea nitrogen, osmotic pressure, and creatinine between the 2 groups before treatment (P=0.146, 0.978, 0.786, 0.983). After treatment, blood urea nitrogen and creatinine in the dual-treatment group were lower than in the control group, and the osmotic pressure was higher than that in the control group (P=0.000, 0.000, 0.000). The dual-treatment group experienced a lower prevalence of dizziness (5.7%), anemia (7.5%), bone pain (7.5%), hypertension (3.8%), and pruritus (5.7%) than the control group (P<0.05). CONCLUSIONS Compared with hemoperfusion alone, hemodialysis+hemoperfusion significantly reduced pruritus and anemia, improved renal function, and was associated with significantly fewer adverse events in patients with diabetic ketoacidosis and acute renal failure.
伴有急性肾衰竭的急性肾损伤与严重的糖尿病酮症酸中毒有关。本研究是在中国的一家单中心进行的,旨在比较联合血液透析和血液灌流(血液透析+血液灌流)与单纯血液灌流在 106 例糖尿病酮症酸中毒合并急性肾衰竭患者中的疗效。
根据不同的透析方案,将 106 例患者分为两组,每组 53 例。血液透析采用单泵 4008S FX8 Helix-One 空心纤维血液透析器(费森尤斯医疗保健公司,德国圣温德尔)进行。血液灌流采用 HA130 树脂吸附剂进行。
两组患者的性别、年龄、糖尿病病程、糖化血红蛋白(A1c)、pH 值和入院时血糖比较,差异均无统计学意义(P=0.54、0.564、0.53、0.78、0.82、0.51)。两组患者治疗前的空腹血糖、血尿素氮、渗透压和肌酐比较,差异均无统计学意义(P=0.146、0.978、0.786、0.983)。治疗后,联合治疗组的血尿素氮和肌酐低于对照组,渗透压高于对照组(P=0.000、0.000、0.000)。联合治疗组头晕(5.7%)、贫血(7.5%)、骨痛(7.5%)、高血压(3.8%)和瘙痒(5.7%)的发生率低于对照组(P<0.05)。
与单纯血液灌流相比,血液透析+血液灌流可显著减少糖尿病酮症酸中毒合并急性肾衰竭患者的瘙痒和贫血,改善肾功能,且不良事件发生率显著降低。