Suppr超能文献

在可膨胀阴茎假体植入时,侧向腹膜后替代储水器位置的结果。

Outcomes of Alternative Reservoir Placement in the Lateral Retroperitoneum During Inflatable Penile Prosthesis Placement.

机构信息

USC Institute of Urology, USC/Norris Comprehensive Cancer Center, Keck School of Medicine, University of Southern California, Los Angeles, CA.

USC Institute of Urology, USC/Norris Comprehensive Cancer Center, Keck School of Medicine, University of Southern California, Los Angeles, CA.

出版信息

Urology. 2021 Jun;152:35-41. doi: 10.1016/j.urology.2021.02.021. Epub 2021 Feb 26.

Abstract

OBJECTIVES

To describe outcomes of reservoir placement, exchange, and extraction from the lateral retroperitoneum (LR) in complex patients with a three-piece inflatable penile prosthesis (IPP).

METHODS

A retrospective chart review was performed on all patients that underwent placement of an IPP from 2009 to 2019. Patients with placement of the reservoir in the LR were identified. Intraoperative complications during reservoir placement, exchange, or removal, reservoir-related outcomes, and secondary device-related outcomes were collated and compared to patients who underwent traditional Space of Retzius reservoir placement.

RESULTS

A total of 587 men underwent primary IPP placement with 321 patients undergoing reservoir placement in the SOR and 266 in the LR. No significant differences were found in intra-operative reservoir-related outcomes (P=.272) between the 2 groups during placement, replacement, or extraction. Bowel injury occurred in 1 patient in the LR group during placement. No significant differences were found in postoperative reservoir complications (P= .534). Both groups each had one instance of patient reported bulge and pain at reservoir site (P= .6777). Two (0.6%) patients in the SOR group and 3 (1.1%) patients in the LR group had a reservoir failure or leak. There was a trend towards a lower rate of device infections in the LR group (1.9%) compared to the SOR group (4.7%) (P= .063). There were no significant differences in overall device mechanical failure rates between both groups (P= .919).

CONCLUSIONS

Reservoir placement in the LR is safe in patients with complex pelvic anatomy with equivalent device durability and no difference in surgical outcomes compared to standard retropubic reservoir placement.

摘要

目的

描述三件式可膨胀阴茎假体(IPP)复杂患者中从侧后腹膜(LR)进行储液器放置、更换和取出的结果。

方法

对 2009 年至 2019 年期间接受 IPP 植入的所有患者进行了回顾性图表审查。确定了将储液器放置在 LR 中的患者。整理并比较了储液器放置、更换或取出过程中的术中并发症、储液器相关结果和继发性设备相关结果,与接受传统Retzius 间隙储液器放置的患者进行比较。

结果

共有 587 名男性接受了初次 IPP 植入,其中 321 名患者在 SOR 中进行了储液器放置,266 名患者在 LR 中进行了储液器放置。两组患者在放置、更换或取出储液器时,术中与储液器相关的结果(P=.272)无显著差异。1 名患者在 LR 组放置储液器时发生肠损伤。两组患者术后储液器并发症(P=.534)无显著差异。两组患者各有 1 例患者报告储液器部位有肿块和疼痛(P=.6777)。SOR 组中有 2 名(0.6%)患者和 LR 组中有 3 名(1.1%)患者出现储液器故障或泄漏。LR 组(1.9%)的设备感染率低于 SOR 组(4.7%)(P=.063),有趋势差异。两组患者的设备机械故障率无显著差异(P=.919)。

结论

在复杂骨盆解剖患者中,LR 中的储液器放置是安全的,与标准Retzius 间隙储液器放置相比,设备耐用性相同,手术结果无差异。