Das Sudipta Sekhar, Sen Subrata, Zaman R U, Biswas Rathindra Nath
Department of Transfusion Medicine, Apollo Gleneagles Hospitals, Kolkata, 700054 India.
Indian J Hematol Blood Transfus. 2021 Jan;37(1):134-139. doi: 10.1007/s12288-020-01337-1. Epub 2020 Aug 16.
The increases in major surgeries, transplantations and speciality clinics have significantly increased the utilization of platelet concentrates including single donor platelets (SDP). The advantages of SDP or apheresis platelet have been discussed elaborately by previous authors as compared to random donor platelets. Here we share our experiences of plateletpheresis procedures using the modern apheresis machines with regards to product quality and donor safety. This study included 3016 procedures of plateletpheresis (1397 on Amicus and 1619 on Trima accel cell separators) on eligible donors using recommended apheresis kits. A target yield of 3 × 10 was set as the end point of each procedure. Donor details, procedure details and donor adverse reactions if any were documented. Statistical analysis was done using the SPSS statistical package (version 13, USA). Of the total 6276 donors screened 2049 (32.6%) were deferred due to various reasons. Out of remaining 4227 eligible donors; 3016 (71.4%) underwent plateletphereis procedures based on the requirement of SDP by the patients. Mean pre-procedure platelet count and hematocrit in donors were 188.3 × 10/mL and 41.7% respectively. Mean procedure time in Amicus (76.6 min) was significantly more than the Trima accel (64.3 min) ( = 0.02). Platelet yield by Trima accel and Amicus was 2.96 × 10 and 3.08 × 10 respectively ( = 0.061). A total of 40 donors (1.33%) suffered adverse effect during or after apheresis procedures. While the modern plateletpheresis devices are both donor and user friendly at the same time they provide quality product consistently in lesser time.
大手术、移植手术和专科门诊数量的增加显著提高了血小板浓缩物的使用量,包括单采血小板(SDP)。与随机供者血小板相比,先前的作者已详细讨论了单采血小板或机采血小板的优势。在此,我们分享使用现代血液成分分离机进行血小板单采术在产品质量和供者安全方面的经验。本研究纳入了3016例符合条件的供者使用推荐的血液成分分离试剂盒进行的血小板单采术(使用Amicus血液成分分离机进行1397例,使用Trima Accel细胞分离机进行1619例)。将目标采集量3×10设定为每个手术的终点。记录供者详细信息、手术细节以及供者的不良反应(如有)。使用SPSS统计软件包(美国,第13版)进行统计分析。在总共筛查的6276名供者中,2049名(32.6%)因各种原因被延期。在其余4227名符合条件的供者中,3016名(71.4%)根据患者对单采血小板的需求接受了血小板单采术。供者术前平均血小板计数和血细胞比容分别为188.3×10/mL和41.7%。使用Amicus血液成分分离机的平均手术时间(76.6分钟)显著长于使用Trima Accel细胞分离机的平均手术时间(64.3分钟)(P = 0.02)。使用Trima Accel细胞分离机和Amicus血液成分分离机的血小板采集量分别为2.96×10和3.08×10(P = 0.061)。共有40名供者(1.33%)在单采术期间或术后出现不良反应。现代血小板单采设备对供者和使用者都很友好,同时能在更短时间内持续提供优质产品。