SA Pathology - Flinders Medical Centre and Royal Adelaide Hospital, South Australia, Australia.
Royal Adelaide Hospital, Adelaide, South Australia, Australia.
Transfusion. 2021 May;61(5):1578-1585. doi: 10.1111/trf.16366. Epub 2021 Mar 17.
Cryoprecipitate has a short post-thaw expiry time of 6 h. The aim of this study was to assess the stability and function of cryoprecipitate components (FVIII, fibrinogen, vWF, and FXIII) and cryoprecipitate sterility up to 120 h post-thawing when stored at two temperatures (2-6°C and room temperature [20-24°C]).
Twenty batches (110 individual units) of time-expired, thawed cryoprecipitate were collected. Units were sampled at the 6-h expiration mark and then stored at 2-6°C or room temperature (RT). They were resampled every 24 h for 120 h. One unit from each batch was sent for sterility testing at 120 h. Samples had FVIII (one stage and chromogenic), fibrinogen, FXIII, vWFag, and vWF:RCo assays performed in batches. Rotational thromboelastometry (ROTEM) was also performed.
FVIII levels declined significantly at 120 h post-thawing at both RT and 2-6°C, but still met international standards for FVIII content. Fibrinogen, vWF antigen, and FXIII levels reduced minimally over 120 h and always met international standard requirements when stored at either temperature. ROTEM analysis demonstrated that fibrinogen function was not compromised at 120 h post-thawing under both storage conditions. vWF:RCo levels declined significantly over 120 h at both storage temperatures. No bacterial contamination was detected in 20 units of cryoprecipitate following storage for 120 h post-thawing.
These results demonstrate that extension of the storage time of thawed cryoprecipitate to 120 h, stored at either 2-6°C or RT, is feasible while still maintaining required FVIII, fibrinogen, and vWFag levels. Storage at 2-6°C has the advantage of reduced risk of potential bacterial contamination.
冷沉淀的解冻后保质期很短,只有 6 小时。本研究旨在评估解冻后的冷沉淀成分(FVIII、纤维蛋白原、vWF 和 FXIII)的稳定性和功能,以及在解冻后 120 小时内,在两种温度(2-6°C 和室温[20-24°C])下储存时的冷沉淀无菌性。
收集了 20 批(110 个单位)过期解冻的冷沉淀。在 6 小时过期标记时对单位进行采样,然后在 2-6°C 或室温(RT)下储存。在 120 小时内每 24 小时重新采样一次。每个批次的一个单位在 120 小时时进行无菌性检测。分批进行 FVIII(一步法和显色法)、纤维蛋白原、FXIII、vWFag 和 vWF:RCo 检测。还进行了旋转血栓弹性测定(ROTEM)。
在 RT 和 2-6°C 下,解冻后 120 小时 FVIII 水平显著下降,但仍符合 FVIII 含量的国际标准。纤维蛋白原、vWF 抗原和 FXIII 水平在 120 小时内略有下降,但在两种温度下储存时均符合国际标准要求。ROTEM 分析表明,在两种储存条件下,解冻后 120 小时内纤维蛋白原功能不受影响。在两种储存温度下,vWF:RCo 水平在 120 小时内显著下降。在解冻后 120 小时储存后,20 个单位的冷沉淀未检测到细菌污染。
这些结果表明,将解冻后的冷沉淀储存时间延长至 120 小时,在 2-6°C 或 RT 下储存是可行的,同时仍能保持所需的 FVIII、纤维蛋白原和 vWFag 水平。在 2-6°C 下储存具有降低潜在细菌污染风险的优势。