Suppr超能文献

基于六分钟步行试验(6MWT)和 Borg RPE 量表的运动耐量分析 - 腹股沟疝修补术前和术后男性。

Analysis of exercise tolerance on the basis of six-minute walk test - 6MWT and Borg RPE scale in men with inguinal hernia before and after Lichtenstein repair.

机构信息

Department of Endocrine, General and Vascular Surgery Medical University of Lodz.

Department of Endocrinological, General and Oncological Surgery, Provincial Multispecialist Center of Oncology and Traumatology named after M. Kopernika in Lodz.

出版信息

Pol Przegl Chir. 2020 Sep 30;93(1):1-8. doi: 10.5604/01.3001.0014.4207.

Abstract

<b>Introduction:</b> Assessment of exercise tolerance (ET) plays an important role in qualifications for treatment and rehabilitation. <br><b>Aim: </b>The aim of the study was to assess ET in patients before and after inguinal hernia operations with Lichtenstein method. <br><b>Material and methods:</b> The cohort study included men with inguinal hernia divided into the study group (SG) (n = 50) and control (CG) (n = 50) undergone the Lichtenstein surgery. Patients from the SG met the criterion of coexistence of cardiovascular and respiratory diseases. Day before and on the second day after surgery, patients performed 6MWT and subjectively rate the exertion according to Borg- RPE- Scale (before, immediately after and 10 minutes after the test). 6MWT distance, Borg scale ratings were analysed. On the second day after surgery 66% of patients from the SG and 58% from the CG did not complete the test. Patients from the SG before (500,07 ± 40,38 m) and on the second day after surgery (243,46 ± 18,18 m) achieved shorter distances compared to the CG (565,93 ± 20,41 m; 249,47 ± 26,66 m), p < 0,001 i p = 0,481. A statistically significant negative correlation between 6MWT distance before surgery and age of the patients was confirmed. Patients who did not develop complications achieved significantly longer distances on admission (p = 0,003 for SG, p = 0,004 for CG). For 6MWT before surgery and 2 days after surgery, patients from the SG showed a significantly higher level of fatigue compared to the CG after the test (before: p = 0,001, after: p = 0,001). Patients form the SG often discontinued 6MWT and less tolerated effort compared to the CG. Hence, 6MWT is useful tool for ascertaining physical capacity and ET.

摘要

<b>引言:</b>评估运动耐量(ET)在治疗和康复资格评估中起着重要作用。<br><b>目的:</b>本研究的目的是评估采用 Lichtenstein 方法治疗腹股沟疝后患者的 ET。<br><b>材料与方法:</b>本队列研究纳入了接受 Lichtenstein 手术的男性腹股沟疝患者,分为研究组(SG)(n = 50)和对照组(CG)(n = 50)。SG 组患者符合合并心血管和呼吸系统疾病的标准。手术前一天和术后第二天,患者进行 6MWT,并根据 Borg-RPE 量表(测试前、测试后即刻和测试后 10 分钟)主观评估用力程度。分析 6MWT 距离和 Borg 量表评分。术后第二天,SG 组 66%的患者和 CG 组 58%的患者未完成测试。SG 组患者术前(500.07 ± 40.38 m)和术后第二天(243.46 ± 18.18 m)的距离均短于 CG 组(565.93 ± 20.41 m;249.47 ± 26.66 m),p < 0.001 i p = 0.481。术前 6MWT 距离与患者年龄呈显著负相关。无并发症患者入院时的距离明显更长(SG 组 p = 0.003,CG 组 p = 0.004)。对于术前和术后 2 天的 6MWT,SG 组患者在测试后比 CG 组表现出更高的疲劳水平(前:p = 0.001,后:p = 0.001)。与 CG 组相比,SG 组患者经常停止 6MWT,且难以耐受体力活动。因此,6MWT 是评估体力和 ET 的有用工具。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验