Jiang Hui-Min, Liang Kun, Tao Li-Ming
Department of Ophthalmology, the Second Hospital Affiliated to Anhui Medical University, Hefei 230601, Anhui Province, China.
Int J Ophthalmol. 2021 Mar 18;14(3):378-382. doi: 10.18240/ijo.2021.03.07. eCollection 2021.
To compare the rotational stability of Toric intraocular lens (IOLs) implantation combined with four-eyelet or two-eyelet capsular tension rings (CTRs) in eyes with high myopia and cataract.
This prospective randomized controlled interventional study included 33 eyes which had preoperative corneal astigmatism ≥1.5 D and ocular axial length ≥25.5 mm. These eyes were randomly divided into two groups to undergo phacoemulsification and toric IOL implantation with either four-eyelet CTR implantation (group A, =16) or two-eyelet CTR implantation (group B, =17). Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), phoropter examination results, and toric IOL rotation degrees were tested 6mo after the surgery.
In both groups, the toric IOL was in the capsular sac 6mo after surgery. The difference between the two groups in terms of visual outcome was not found to be statistically significant (>0.05) at a follow-up of 6mo. The mean residual astigmatism values were 0.56±0.22 D and 0.92±0.24 D in A and B groups, respectively (<0.001). The mean rotation degree of IOL was 1.00°±0.73° in group A and 3.53°±1.46° in group B (<0.001).
In cataract patients with high myopia and astigmatism, four-eyelet CTR can effectively increase the rotation stability of toric IOLs, achieving the desired goal of correcting corneal astigmatism.
比较在高度近视合并白内障患者眼中植入散光型人工晶状体(IOL)联合四孔或双孔囊袋张力环(CTR)后的旋转稳定性。
这项前瞻性随机对照干预研究纳入了33只术前角膜散光≥1.5 D且眼轴长度≥25.5 mm的眼睛。这些眼睛被随机分为两组,分别接受白内障超声乳化吸除联合四孔CTR植入散光型IOL手术(A组,n = 16)或双孔CTR植入散光型IOL手术(B组,n = 17)。术后6个月检测裸眼视力(UCVA)、最佳矫正视力(BCVA)、综合验光仪检查结果以及散光型IOL的旋转度数。
两组患者术后6个月时散光型IOL均位于囊袋内。随访6个月时,两组在视力结果方面的差异无统计学意义(P>0.05)。A组和B组的平均残余散光值分别为0.56±0.22 D和0.92±0.24 D(P<0.001)。A组IOL的平均旋转度数为1.00°±0.73°,B组为3.53°±1.46°(P<0.001)。
在高度近视合并散光的白内障患者中,四孔CTR可有效提高散光型IOL的旋转稳定性,达到矫正角膜散光的预期目标。