Abstract

OBJECTIVES

To compare three-dimensional high-resolution magnetic resonance imaging (3D HR-MRI) and digital subtraction angiography (DSA) for diagnosing and evaluating stenosis in the entire circle of Willis.

METHODS

The study included 516 intracranial arteries from 43 patients with intracranial artery stenosis (ICAS) who underwent both 3D HR-MRI and DSA within 1 month. Two readers independently diagnosed atherosclerosis, dissection, moyamoya disease and vasculitis, rated their diagnostic confidence for each vessel and measured the luminal diameters. Reference standard was made from clinico-radiologic diagnosis. Diagnostic accuracy, diagnostic confidence, the degree of stenosis and luminal diameter were assessed and compared between both modalities.

RESULTS

For atherosclerosis, 3D HR-MRI showed better diagnostic accuracy (P = .03-.003), sensitivity (P = .006-.01) and positive predictive value (P ≤ .001-.006) compared to DSA. Overall, the readers were more confident of their diagnosis of ICAS when using 3D HR-MRI (reader 1, P ≤ .001-.007; reader 2, P ≤ .001-.015). 3D HR-MRI showed similar degree of stenosis (P > .05) and higher luminal diameter (P < .05) compared to DSA.

CONCLUSIONS

3D HR-MRI might be useful to evaluate atherosclerosis, with better diagnostic confidence and comparable stenosis measurement compared to DSA in the entire circle of Willis.

KEY POINTS

• 3D HR-MRI showed better diagnostic accuracy for atherosclerosiscompared to DSA • 3D HR-MRI showed better overall diagnostic confidence for stenosiscompared to DSA • 3D HR-MRI and DSA showed similar degree of stenosis.

摘要

目的

比较三维高分辨率磁共振成像(3D HR-MRI)和数字减影血管造影(DSA)在诊断和评估整个 Willis 环狭窄中的作用。

方法

该研究纳入了 43 例颅内动脉狭窄(ICAS)患者的 516 条颅内动脉,这些患者在 1 个月内均接受了 3D HR-MRI 和 DSA 检查。两位读者独立诊断动脉粥样硬化、夹层、烟雾病和血管炎,并对每支血管的诊断信心进行评分,测量管腔直径。参考标准来自临床放射学诊断。评估并比较了两种方法的诊断准确性、诊断信心、狭窄程度和管腔直径。

结果

对于动脉粥样硬化,3D HR-MRI 显示出更好的诊断准确性(P = .03-.003)、敏感性(P = .006-.01)和阳性预测值(P ≤ .001-.006),优于 DSA。总体而言,读者在使用 3D HR-MRI 时对 ICAS 的诊断更有信心(读者 1,P ≤ .001-.007;读者 2,P ≤ .001-.015)。与 DSA 相比,3D HR-MRI 显示出相似的狭窄程度(P > .05)和更高的管腔直径(P < .05)。

结论

3D HR-MRI 可能有助于评估动脉粥样硬化,与 DSA 相比,其在整个 Willis 环的诊断信心更高,狭窄程度测量更准确。

关键点

  • 3D HR-MRI 对动脉粥样硬化的诊断准确性优于 DSA。

  • 3D HR-MRI 对狭窄的总体诊断信心优于 DSA。

  • 3D HR-MRI 和 DSA 显示出相似的狭窄程度。