Anticancer Res. 2021 Apr;41(4):1951-1958. doi: 10.21873/anticanres.14962.
BACKGROUND/AIM: This study focused on the hybrid-volumetric modulated arc therapy (hVMAT) for stage I esophageal cancer and compared the effects on dose distribution induced by changes in the ratio of three-dimensional conformal radiotherapy (3DCRT) to VMAT.
Fifteen patients who underwent 3DCRT for cT1bN0M0 esophageal cancer at Kanagawa Cancer Center from January 2014 to April 2019 were included in the study. The dose-volume histogram (DVH) parameters of the target volume and normal organs were evaluated in the 3DCRT, hVMAT, and VMAT treatment plans.
The homogeneity index of the target volume was significantly lower for hVMAT. In hVMAT, as the ratio of VMAT increased, the volume of low-dose region in the heart and lung increased, whereas the volume of the middle- to high-dose region decreased. As the ratio of VMAT increased, the mean dose in the heart decreased, whereas the mean dose in the lung increased.
Favorable dose concentration was obtained for the target volume in hVMAT for stage I esophageal cancer. Altering the ratio of VMAT significantly changed the DVH parameters in normal organs.