To determine the pachymetric and corneal endothelial cell morphometric features and their relationship to ocular and systemic factors in healthy Congolese subjects.
Non-contact specular microscopy was used in 278 healthy eyes (278 subjects) to measure central corneal thickness (CCT), corneal endothelial cell density (CECD) along with cell size, coefficient of variation (CV) in cell size, and hexagonality (HEX). The lower and upper reference limits and average values for each parameter were determined. Correlation and association of average values with anthropo-demographic and clinical variables were assessed.
The mean age was 38.9 ± 17.2 years (10.9-80.7 years). Average values were 504.2 ± 30.7 μm (CCT), 2907.1 ± 290.9 cells/mm (CECD), 348.5 ± 38.4 μm (cell size), 32.9 ± 3.6% (CV), and 51.8 ± 7.2% (HEX). CCT was 504.9 ± 33.6 μm in men and 503.6 ± 28.3 μm in women (p = .73); values for CECD were 2917.1 ± 253.5 cells/mm and 2899.2 ± 317.8 cells/mm (p = 0.61), respectively. Lower and upper reference limits were 449.6 μm and 566.0 μm for CCT, and 2165.3 cells/mm and 3414.4 cells/mm for CECD, respectively. CCT correlated with body mass index (BMI), (r = - 0.12, P = 0.04). CECD decreased with age (r = - 0.49, P < 0.001), BMI (r = - 0.20, P = 0.001), intraocular pressure (r = - 0.13, P = 0.029) and ocular perfusion pressure (r = - 0.28, P = 0.028). CECD decayed by 8.3 cells/mm or 0.30% per year of age and CCT decreased by 0.72 μm per kg/m.
Mean central cornea was thinner, CECD higher, and references limits lower than reported in other African populations. The CCT and CECD normative values reported herein will be useful for both clinical and research purposes in this population.
确定健康刚果受试者的角膜厚度测量值和角膜内皮细胞形态测量特征及其与眼部和全身因素的关系。
对278只健康眼睛(278名受试者)使用非接触式角膜内皮显微镜测量中央角膜厚度(CCT)、角膜内皮细胞密度(CECD)以及细胞大小、细胞大小变异系数(CV)和六角形细胞比例(HEX)。确定每个参数的下限和上限参考值以及平均值。评估平均值与人口统计学和临床变量的相关性和关联性。
平均年龄为38.9±17.2岁(10.9 - 80.7岁)。平均值分别为504.2±30.7μm(CCT)、2907.1±290.9个细胞/mm²(CECD)、348.5±38.4μm(细胞大小)、32.9±3.6%(CV)和51.8±7.2%(HEX)。男性的CCT为504.9±33.6μm,女性为503.6±28.3μm(p = 0.73);CECD值分别为2917.1±253.5个细胞/mm²和2899.2±317.8个细胞/mm²(p = 0.61)。CCT的下限和上限参考值分别为449.6μm和566.0μm,CECD的下限和上限参考值分别为2165.3个细胞/mm²和3414.4个细胞/mm²。CCT与体重指数(BMI)相关(r = -0.12,P = 0.04)。CECD随年龄(r = -0.49,P < 0.001)、BMI(r = -0.20,P = 0.001)、眼压(r = -0.13,P = 0.029)和眼灌注压(r = -0.28,P = 0.028)降低。CECD每年下降8.3个细胞/mm²或0.30%,CCT每kg/m²下降0.72μm。
平均中央角膜比其他非洲人群报道的更薄,CECD更高,参考值下限更低。本文报道的CCT和CECD规范值将对该人群的临床和研究目的均有用。