Tobacco Control Unit, Catalan Institute of Oncology-ICO, WHO Collaborating Centre for Tobacco Control, L'Hospitalet de Llobregat, Barcelona, Spain.
Tobacco Control Research Group, Bellvitge Biomedical Research Institute-IDIBELL, L'Hospitalet de Llobregat, Barcelona, Spain.
Indoor Air. 2021 Sep;31(5):1601-1613. doi: 10.1111/ina.12841. Epub 2021 Apr 27.
Secondhand electronic cigarette (e-cigarette) aerosol (SHA) might impair indoor air quality and expose bystanders. This study aims to investigate exposure to SHA in controlled conditions of enclosed settings simulating real-world scenario. An experiment was performed in a car and in a room, in which SHA was generated during a 30-minute ad libitum use of an e-cigarette. The experiment was replicated on five consecutive days in each setting. We measured PM , airborne nicotine concentrations, and biomarkers of exposure to SHA, such as nicotine metabolites, tobacco-specific nitrosamines, propylene glycol, and glycerol in bystanders' saliva samples before, during, and after the exposure period. Self-reported health symptoms related to exposure to SHA were also recorded. The results showed that the highest median PM concentration was recorded during the exposure period, being 21 µg/m in the room setting and 16 µg/m in the car setting-about twofold increase compared to the baseline. Most concentrations of the airborne nicotine and all biomarkers were below the limit of quantification in both settings. Bystanders in both settings experienced some short-term irritation symptoms, expressed as dry throat, nose, eyes, and phlegm. In conclusion, short-term use of an e-cigarette in confined spaces increased indoor PM level and caused some irritation symptoms in bystanders.
二手电子香烟(电子烟)气溶胶(SHA)可能会降低室内空气质量,并使旁观者暴露在其中。本研究旨在调查在模拟真实场景的封闭环境中,处于控制条件下的旁观者暴露于 SHA 的情况。在汽车和房间内进行了一项实验,在这两个环境中,参与者在 30 分钟内随意使用电子烟,从而产生 SHA。在每个环境中,实验连续五天重复进行。我们测量了 PM 、空气中的尼古丁浓度,以及旁观者唾液样本中暴露于 SHA 的生物标志物,如尼古丁代谢物、烟草特异性亚硝胺、丙二醇和甘油。在暴露期间以及之后,还记录了与暴露于 SHA 相关的自我报告的健康症状。结果表明,在暴露期间记录到的最高中位 PM 浓度最高,在房间设置中为 21 µg/m ,在汽车设置中为 16 µg/m ,与基线相比增加了约两倍。在这两个环境中,大多数空气中尼古丁和所有生物标志物的浓度都低于定量限。在这两个环境中,旁观者都经历了一些短期刺激症状,表现为喉咙、鼻子、眼睛和痰干燥。总之,在封闭空间内短期使用电子烟会增加室内 PM 水平,并导致旁观者出现一些刺激症状。