Validation of the soft-embalmed Thiel cadaver as a high-fidelity simulator of pressure during targeted nerve injection.

机构信息

Department of Anaesthesia, Ninewells Hospital, Dundee, UK

Institute of Academic Anaesthesia, University of Dundee, Dundee, UK.

出版信息

Reg Anesth Pain Med. 2021 Jun;46(6):540-548. doi: 10.1136/rapm-2020-102132. Epub 2021 Apr 27.

Abstract

INTRODUCTION

Although administration of regional anesthesia nerve blocks has increased during the COVID-19 pandemic, training opportunities in regional anesthesia have reduced. Simulation training may enhance skills, but simulators must be accurate enough for trainees to engage in a realistic way-for example, detection of excessive injection pressure. The soft-embalmed Thiel cadaver is a life-like, durable simulator that is used for dedicated practice and mastery learning training in regional anesthesia. We hypothesized that injection opening pressure in perineural tissue, at epineurium and in subepineurium were similar to opening pressures measured in experimental animals, fresh frozen cadavers, glycol soft-fix cadavers and patients.

METHODS

We systematically reviewed historical data, then conducted three validation studies delivering a 0.5 mL hydrolocation bolus of embalming fluid and recording injection pressure. First, we delivered the bolus at 12 mL/min at epimysium, perineural tissue, epineurium and in subepineurium at 48 peripheral nerve sites on three cadavers. Second, we delivered the bolus at using three infusion rates: 1 mL/min, 6 mL/min and 12 mL/min on epineurium at 70 peripheral nerve sites on five cadavers. Third, we repeated three injections (12 mL/min) at 24 epineural sites over the median and sciatic nerves of three cadavers.

RESULTS

Mean (95%) injection pressure was greater at epineurium compared with subepineurium (geometric ratio 1.2 (95% CI: 0.9 to 1.6)), p=0.04, and perineural tissue (geometric ratio 5.1 (95% CI: 3.7 to 7.0)), p<0.0001. Mean (95%) injection pressure was greater at 12 mL/min compared with 1 mL/min (geometric ratio 1.6 (95% CI: 1.2 to 2.1), p=0.005). Pressure measurements were similar in study 3 (p>0.05 for all comparisons).

DISCUSSION

We conclude that the soft-embalmed Thiel cadaver is a realistic simulator of injection opening pressure.

摘要

简介

尽管 COVID-19 大流行期间区域麻醉神经阻滞的应用有所增加,但区域麻醉的培训机会却减少了。模拟培训可以提高技能,但模拟器必须足够准确,以便学员能够以真实的方式进行训练,例如检测注射压力过高。经过软固定的蒂尔尸体是一种逼真、耐用的模拟器,用于区域麻醉的专门练习和掌握学习培训。我们假设,在神经周围组织、神经外膜和神经内膜中的注射开口压力与在实验动物、新鲜冷冻尸体、乙二醇软固定尸体和患者中测量的开口压力相似。

方法

我们系统地回顾了历史数据,然后进行了三项验证研究,即在三个尸体的 48 个周围神经部位的神经外膜、神经周围组织、神经外膜和神经内膜以 12 mL/min 的速度注射 0.5 mL 的固定液水凝胶,并记录注射压力。首先,我们在三个尸体的 12 个部位以 12 mL/min 的速度在神经外膜、神经周围组织、神经外膜和神经内膜上注射了固定液水凝胶。其次,我们在五个尸体的 70 个神经部位以 1、6 和 12 mL/min 的三个输注速度在神经外膜上注射了固定液水凝胶。第三,我们在三个尸体的正中神经和坐骨神经的 24 个神经外膜部位重复了三次注射(12 mL/min)。

结果

与神经内膜相比,神经外膜的平均(95%CI)注射压力更高(几何比 1.2(95%CI:0.9 至 1.6)),p=0.04,与神经周围组织(几何比 5.1(95%CI:3.7 至 7.0))相比,p<0.0001。与 1 mL/min 相比,12 mL/min 时的平均(95%CI)注射压力更高(几何比 1.6(95%CI:1.2 至 2.1)),p=0.005)。在研究 3 中,压力测量结果相似(p>0.05)。

讨论

我们的结论是,软固定的蒂尔尸体是一种模拟注射开口压力的逼真模拟器。