This study evaluated the resistance to flexural fatigue and torsional strength of files for glide path preparation in continuous rotation or Optimum Glide Path motion (OGP). ScoutRace 15.02 and ProGlider 16.02 files were used in a dynamic testing device during preparation of simulating curved root canals (40-degree curvature and 5 mm radius). For the torsional test, a machine was used to test torsion measured maximum torsional strength (N.cm). Two-way anova and Tukey's multiple comparisons test were used for statistical analysis. Files in OGP motion had a statistically better resistance to flexural fatigue (P < 0.05). ProGlider files took longer time to failure than ScoutRace files only when OGP was used (P < 0.05). The torsional test revealed that OGP produced significantly less torsional stress than rotary motions for both types of glide path files (P < 0.05) In conclusion, OGP motion increased substantially the mechanical safety of endodontic glide path files.
本研究评估了用于连续旋转或最佳滑行路径运动(OGP)中滑行路径预备的锉针的抗弯曲疲劳性和抗扭强度。在模拟弯曲根管(40度弯曲度和5毫米半径)预备过程中,在动态测试装置中使用了ScoutRace 15.02和ProGlider 16.02锉针。对于扭转测试,使用一台机器测试扭转,测量最大抗扭强度(N.cm)。采用双向方差分析和Tukey多重比较检验进行统计分析。采用OGP运动的锉针在抗弯曲疲劳方面具有统计学上更好的表现(P<0.05)。仅在采用OGP时,ProGlider锉针比ScoutRace锉针达到折断所需的时间更长(P<0.05)。扭转测试显示,对于两种类型的滑行路径锉针,OGP产生的扭转应力均显著低于旋转运动(P<0.05)。总之,OGP运动显著提高了根管滑行路径锉针的机械安全性。