To compare the cyclic fatigue resistance (CFR) of PathFile, ProGlider and ScoutRaCe nickel-titanium (NiTi) rotary instruments used in an S-shaped artificial canal.
A total of 90 instruments were tested in an S-shaped artificial canal (n = 30 for each group: PathFile (size 16, 2% constant taper), ProGlider (size 16, variable taper between 2% and 8% along the shaft) and ScoutRaCe (size 15, 2% constant taper). All files were rotated until fracture. The number of cycles to failure was counted to determine CFR. The length of each fractured fragment was measured in millimetres. The CFR was analysed statistically with the Kruskal-Wallis test. The fragment length was analysed using one-way analysis of variance and Tukey's post hoc tests.
The ProGlider instruments were associated with significantly greater CFR than the PathFile and ScoutRaCe files in the apical curvature (P < 0.05). There was no significant difference between the CFR of the PathFile and ScoutRaCe files in the apical curvature (P > 0.05). ProGlider, PathFile and ScoutRaCe instruments exhibited similar CFR in the coronal curvature (P > 0.05).
The ProGlider files had greater cyclic fatigue resistance than the PathFile and ScoutRaCe files in the apical curvature of an artificial S-shaped canal.
比较在 S 形人工根管中使用的 PathFile、ProGlider 和 ScoutRaCe 镍钛(NiTi)旋转器械的循环疲劳阻力(CFR)。
在 S 形人工根管中对 90 个器械进行了测试(每组 30 个:PathFile(16 号,2% 恒定锥度)、ProGlider(16 号,轴上 2%至 8%之间的变锥度)和 ScoutRaCe(15 号,2% 恒定锥度)。所有器械均旋转至断裂。记录断裂前的循环次数以确定 CFR。以毫米为单位测量每个断裂片段的长度。使用 Kruskal-Wallis 检验对 CFR 进行统计学分析。使用单向方差分析和 Tukey 事后检验分析片段长度。
在根尖弯曲处,ProGlider 器械的 CFR 明显大于 PathFile 和 ScoutRaCe 器械(P<0.05)。PathFile 和 ScoutRaCe 器械在根尖弯曲处的 CFR 无显著差异(P>0.05)。在冠部弯曲处,ProGlider、PathFile 和 ScoutRaCe 器械的 CFR 相似(P>0.05)。
在人工 S 形根管的根尖弯曲处,ProGlider 器械的循环疲劳阻力大于 PathFile 和 ScoutRaCe 器械。