Werner Maren, Pervan Philip, Glück Vivian, Zeman Florian, Koller Michael, Burkhardt Ralph, Glück Thomas, Wenzel Jürgen J, Schmidt Barbara, Gessner André, Peterhoff David
Institute for Medical Microbiology and Hygiene, University of Regensburg, 93053 Regensburg, Germany.
Institute for Clinical Microbiology and Hygiene, University Hospital Regensburg, 93053 Regensburg, Germany.
J Clin Med. 2021 Apr 8;10(8):1580. doi: 10.3390/jcm10081580.
Serological testing is crucial in detection of previous infection and in monitoring convalescent and vaccine-induced immunity. During the Severe Acute Respiratory Syndrome Corona Virus 2 (SARS-CoV-2) pandemic, numerous assay platforms have been developed and marketed for clinical use. Several studies recently compared clinical performance of a limited number of serological tests, but broad comparative evaluation is currently missing. Within this study, a panel of 161 sera from SARS-CoV-2 infected, seasonal CoV-infected and SARS-CoV-2 naïve subjects was enrolled to evaluate 16 ELISA/ECLIA-based and 16 LFA-based tests. Specificities of all ELISA/ECLIA-based assays were acceptable and generally in agreement with the providers' specifications, but sensitivities were lower as specified. Results of the LFAs were less accurate as compared to the ELISAs, albeit with some exceptions. We found a sporadic unequal immune response for different antigens and thus recommend the use of a nucleocapsid protein (N)- and spike protein (S)-based test combination when maximal sensitivity is necessary. Finally, the quality of the immune response in terms of neutralization should be tested using S-based IgG tests.
血清学检测对于检测既往感染以及监测康复期和疫苗诱导的免疫至关重要。在严重急性呼吸综合征冠状病毒2(SARS-CoV-2)大流行期间,已开发并上市了多种用于临床的检测平台。最近有几项研究比较了有限数量血清学检测的临床性能,但目前尚缺乏广泛的比较评估。在本研究中,纳入了一组来自感染SARS-CoV-2、季节性冠状病毒感染和未感染SARS-CoV-2受试者的161份血清,以评估16种基于酶联免疫吸附测定/电化学发光免疫分析(ELISA/ECLIA)的检测和16种基于侧向流动分析法(LFA)的检测。所有基于ELISA/ECLIA的检测的特异性均可接受,且总体上与供应商的规格一致,但敏感性低于规定值。与ELISA相比,LFA的结果准确性较低,不过也有一些例外情况。我们发现针对不同抗原存在散发性的不等免疫反应,因此建议在需要最大敏感性时使用基于核衣壳蛋白(N)和刺突蛋白(S)的检测组合。最后,应使用基于S蛋白的IgG检测来检测中和方面的免疫反应质量。