Bartels H L, van der Lei B
Central Animal Laboratory, University of Groningen, The Netherlands.
Lab Anim. 1988 Apr;22(2):122-6. doi: 10.1258/002367788780864556.
130 Male Wistar rats, 2-3 months old and weighing 250-350 g were operated on to implant biodegradable small-calibre vascular prostheses (length 10 mm; internal diameter 1.5 mm) in their infrarenal abdominal aorta. The mean operation time was 40 min, the mean aortic cross-clamping time 25 min. The early patency rate was 100%, the late patency rate was 97.7%, and the operative mortality was 3.1%. Microscopical examination of the biodegradable prostheses from 1 h up to 1 year after implantation demonstrated reproducible morphological results; in these prostheses a new arterial wall regenerated which had a structure very similar to the normal arterial wall. It was concluded that the rat is an appropriate experimental laboratory animal for testing new types of small-calibre vascular prostheses.
选取130只2 - 3月龄、体重250 - 350克的雄性Wistar大鼠,对其进行手术,在肾下腹主动脉植入可生物降解的小口径血管假体(长度10毫米;内径1.5毫米)。平均手术时间为40分钟,平均主动脉阻断时间为25分钟。早期通畅率为100%,晚期通畅率为97.7%,手术死亡率为3.1%。对植入后1小时至1年的可生物降解假体进行显微镜检查,结果显示形态学结果具有可重复性;在这些假体中,再生出了一个新的动脉壁,其结构与正常动脉壁非常相似。得出的结论是,大鼠是测试新型小口径血管假体的合适实验动物。