Suppr超能文献

持续使用可调膝关节的膝踝足矫形器对脑卒中偏瘫患者膝关节活动及肌肉活动变化的影响

Knee joint movement and muscle activity changes in stroke hemiplegic patients on continuous use of knee-ankle-foot orthosis with adjustable knee joint.

作者信息

Murayama Minoru

机构信息

Funabashi Municipal Rehabilitation Hospital: 4-26-1 Natsumidai, Funabashi, Chiba 273-0866, Japan.

出版信息

J Phys Ther Sci. 2021 Apr;33(4):322-328. doi: 10.1589/jpts.33.322. Epub 2021 Apr 6.

Abstract

[Purpose] We aimed to evaluate knee joint movement and muscle activity ratio changes in stroke hemiplegic patients in recovery phase after using a knee-ankle-foot orthosis with an adjustable knee joint for 1 month; we also aimed to discuss the practical implications of our findings. [Participants and Methods] The participants were 8 hemiplegic patients in the recovery phase of stroke who were prescribed knee-ankle-foot orthosis with adjustable knee joint. We measured knee joint angles and electromyographic activity of the vastus medialis and biceps femoris during walking in two conditions: the knee-ankle-foot orthosis knee joint fixed in the extended position and the knee joint moved from 0° to 30° in the flexion direction. Measurements were taken 2 weeks after completion to account for habituation of the orthosis and repeated 1 month later. [Results] When the knee joint was moving from 0° to 30° in the flexion direction, the knee joint angle at initial contact and the minimum flexion angle of the gait cycle decreased significantly between the first and second measurements. When knee joint flexion was 30°, the muscle activity ratio of the vastus medialis increased significantly in the loading response and mid-stance compared to when it was fixed. [Conclusion] Setting the knee joint of a knee-ankle-foot orthosis in accordance with the knee joint movement may increase the muscle activity ratio of the vastus medialis from loading response to mid-stance.

摘要

[目的] 我们旨在评估使用可调节膝关节的膝踝足矫形器1个月后,脑卒中偏瘫恢复期患者膝关节运动及肌肉活动比率的变化;我们还旨在探讨研究结果的实际意义。[参与者与方法] 参与者为8例脑卒中恢复期偏瘫患者,他们被开具了可调节膝关节的膝踝足矫形器。我们在两种情况下测量了行走过程中的膝关节角度以及股内侧肌和股二头肌的肌电活动:膝踝足矫形器膝关节固定在伸展位,以及膝关节在屈曲方向从0°移动到30°。在完成佩戴2周后进行测量,以考虑矫形器的适应性,并在1个月后重复测量。[结果] 当膝关节在屈曲方向从0°移动到30°时,首次测量和第二次测量之间,初始接触时的膝关节角度和步态周期的最小屈曲角度显著减小。当膝关节屈曲30°时,与固定时相比,股内侧肌在负重反应期和站立中期的肌肉活动比率显著增加。[结论] 根据膝关节运动设置膝踝足矫形器的膝关节,可能会增加股内侧肌从负重反应期到站立中期的肌肉活动比率。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5e47/8079889/5c70a45a6c83/jpts-33-322-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验