Demilew Basazinew Chekol, Getu Dagninet, Tesfaw Desalegn, Taye Moges Gelaw
Department of Anesthesia, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia.
Department of Public Health, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia.
Ann Med Surg (Lond). 2021 Apr 15;65:102282. doi: 10.1016/j.amsu.2021.102282. eCollection 2021 May.
Spinal anesthesia for cesarean section is now a day a popular plan of anesthesia because of its rapid onset and high frequency of successful blockade. It is a vital monitor to the quality of care in anesthesia. The main aim of this study was to assess the level of maternal satisfaction and associated factors after cesarean section under spinal.
Hospital-based cross-sectional study was conducted on mothers who underwent cesarean section with spinal anesthesia. Descriptive analysis and chi-square test were employed. Bivariable and multivariable logistic regression was used to measure the association of factors with the level of satisfaction. A p-value of ≤0.25 and ≤ 0.05 was used to decide statistical significance for bivariable and multivariable logistic regression respectively.
The overall satisfaction level of parturients after spinal anesthesia was 97(80.2%). The satisfaction level was 83.3% with PONV treatment, 98.3% with intraoperative analgesia, between 52.5% and 64.2% to preoperative activities, and 72.5% for postoperative patient care by the anesthetist. Having previous anesthesia was the independent factor that has a significant association with the level of satisfaction with AOR, 3.94; 95%CI, 1.24-12.45; P- 0.01.
In general, the overall satisfaction of the mothers towards spinal anesthesia was fair with a satisfaction score of 80.2%. Parturients were highly dissatisfied with the preoperative visit and information subscale as compared to the other subscales.
由于剖宫产脊髓麻醉起效迅速且阻滞成功率高,如今它是一种常用的麻醉方案。它是麻醉护理质量的重要监测指标。本研究的主要目的是评估脊髓麻醉下剖宫产术后产妇的满意度水平及相关因素。
对接受脊髓麻醉剖宫产的母亲进行基于医院的横断面研究。采用描述性分析和卡方检验。使用双变量和多变量逻辑回归来衡量因素与满意度水平的关联。双变量和多变量逻辑回归分别采用≤0.25和≤0.05的p值来确定统计学意义。
脊髓麻醉后产妇的总体满意度为97(80.2%)。恶心呕吐治疗的满意度为83.3%,术中镇痛的满意度为98.3%,术前活动的满意度在52.5%至64.2%之间,麻醉医生术后患者护理的满意度为72.5%。既往有麻醉史是与满意度水平有显著关联的独立因素,比值比为3.94;95%置信区间为1.24 - 12.45;P = 0.01。
总体而言,母亲们对脊髓麻醉的总体满意度尚可,满意度评分为80.2%。与其他分量表相比,产妇对术前访视和信息分量表的满意度较低。