BACKGROUND

Urinary tract infection (UTI) is one of the most frequent reasons for antimicrobial therapy. In typical clinical setting, 18-48 h is needed to identify pathogens by urine culture. A rapid method for pathogenic UTI diagnosis by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been developed in recent years.

METHODS

This meta-analysis systematically evaluated the accuracy of MALDI-TOF MS for direct identification of bacteria from culture-positive urine samples. We queried the electronic database of Medline and Web of Science to obtain relevant articles.

RESULTS

Nineteen articles involving 4,579 isolates were included after final selection in the meta-analysis. The random-effects pooled identification accuracy of MALDI-TOF MS was 0.82 with 95% confidence interval of 0.79 to 0.86 at the species level. For Gram-negative isolates, the correct identification performance of the species ranged from 0.54 to 0.98, with a cumulative rate of 0.87 (95% CI: 0.83 to 0.91). For Gram-positive isolates, the correct identification rate ranged from 0.32 to 0.80, with a cumulative rate of 0.59 (95% CI: 0.49 to 0.68).

CONCLUSIONS

MALDI-TOF MS provides a reliable direct identification of bacteria, particularly in cases of Gram-negative isolates, from clinical urine specimens. Nevertheless, the identification accuracy of this method is moderate for Gram-positive bacteria.

摘要

背景

尿路感染(UTI)是抗菌治疗最常见的原因之一。在典型的临床环境中,通过尿培养鉴定病原体需要18 - 48小时。近年来已开发出一种通过基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)快速诊断致病性UTI的方法。

方法

本荟萃分析系统评价了MALDI-TOF MS直接鉴定培养阳性尿标本中细菌的准确性。我们查询了Medline和Web of Science的电子数据库以获取相关文章。

结果

荟萃分析最终纳入了19篇涉及4579株分离菌的文章。在种水平上,MALDI-TOF MS的随机效应合并鉴定准确性为0.82,95%置信区间为0.79至0.86。对于革兰氏阴性分离菌,种的正确鉴定性能范围为0.54至0.98,累积率为0.87(95%CI:0.83至0.91)。对于革兰氏阳性分离菌,正确鉴定率范围为0.32至0.80,累积率为0.59(95%CI:0.49至0.68)。

结论

MALDI-TOF MS能可靠地直接鉴定临床尿标本中的细菌,尤其是革兰氏阴性分离菌的情况。然而,该方法对革兰氏阳性菌的鉴定准确性中等。