In this issue of , Baumstark et al. evaluated the analytical performance of a bench-top laboratory glucose analyzer (SUPER-GL) intended for replacement for the YSI2300-STAT analyzer, that served for several decades as a comparator method in clinical and analytical studies of blood glucose monitoring systems (BGMS). The authors concluded that the SUPER-GL's overall performance is comparable to that of YSI2300-STAT, and has the potential to be a candidate comparator analyzer. However, the question is if we need to recommend as a "comparator method," a specific device, that measure glucose using the same analytical method with most BGMS. In this analysis we present our point of view hoping to generate a discussion on the necessity for such a replacement.
本期《 》中,Baumstark 等人评估了一款台式实验室葡萄糖分析仪(SUPER-GL)的分析性能,该仪器旨在替代 YSI2300-STAT 分析仪,后者作为一种比较方法在血糖监测系统(BGMS)的临床和分析研究中使用了几十年。作者得出结论,SUPER-GL 的整体性能与 YSI2300-STAT 相当,并且有可能成为候选比较分析仪。然而,问题是我们是否需要推荐一种“比较方法”,即一种使用与大多数 BGMS 相同分析方法测量葡萄糖的特定设备。在本分析中,我们提出了自己的观点,希望就这种替代的必要性展开讨论。