Abstract

OBJECTIVES

The aim of this study was to evaluate the interexaminer reliability for tomographic findings in degenerative temporomandibular joint disease and its agreement with clinical diagnosis.

METHODS

Women aged 18 and 60 years were invited to participate in this research. All participants were evaluated by a single experienced examiner according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). Group 1 was comprised of TMJs with Degenerative Joint Disease (DJD). Group 2 was comprised of healthy TMJs, without any signs and/or symptoms of TMD. All CBCT images were evaluated by 2 calibrated examiners for the image evaluation criteria but blinded for the clinical diagnosis.

RESULTS

From the 194 women evaluated, 41 were included, with a mean age of 35.23 (± 14.06) years. Group 1 was comprised of 26 TMJs with DJD and group 2 of 36 asymptomatic TMJs. The interexaminer reliability was κ = 0.706 (p < 0.000), while agreement between clinical and tomographic findings were κ = 0.301 (p = 0.01) and κ = 0.273 (p = 0.02) for each examiner. The use of CBCT as a diagnostic test had shown sensitivity and specificity values of 61.5% and 75%, respectively.

CONCLUSIONS

The interexaminer reliability for tomographic findings was strong. However, the agreement between clinical and tomographic findings was reasonable, for both examiners.

摘要

目的

本研究旨在评估退行性颞下颌关节疾病断层扫描结果的检查者间可靠性及其与临床诊断的一致性。

方法

邀请年龄在18至60岁之间的女性参与本研究。所有参与者均由一名经验丰富的检查者根据颞下颌关节紊乱病研究诊断标准(RDC/TMD)进行评估。第1组由患有退行性关节疾病(DJD)的颞下颌关节组成。第2组由健康的颞下颌关节组成,无任何颞下颌关节紊乱病的体征和/或症状。所有CBCT图像均由2名经过校准的检查者根据图像评估标准进行评估,但对临床诊断结果不知情。

结果

在接受评估的194名女性中,41名被纳入研究,平均年龄为35.23(±14.06)岁。第1组由26个患有DJD的颞下颌关节组成,第2组由36个无症状的颞下颌关节组成。检查者间可靠性κ = 0.706(p < 0.000),而每位检查者的临床和断层扫描结果之间的一致性κ分别为0.301(p = 0.01)和0.273(p = 0.02)。使用CBCT作为诊断测试时,敏感性和特异性值分别为61.5%和75%。

结论

断层扫描结果的检查者间可靠性很强。然而,对于两位检查者而言,临床和断层扫描结果之间的一致性是合理的。