Abstract

BACKGROUND

To develop a novel subjective-objective-combined (SOC) grading standard for auto-segmentation for each organ at risk (OAR) in the thorax.

METHODS

A radiation oncologist manually delineated 13 thoracic OARs from computed tomography (CT) images of 40 patients. OAR auto-segmentation accuracy was graded by five geometric objective indexes, including the Dice similarity coefficient (DSC), the difference of the Euclidean distance between centers of mass (ΔCMD), the difference of volume (ΔV), maximum Hausdorff distance (MHD), and average Hausdorff distance (AHD). The grading results were compared with those of the corresponding geometric indexes obtained by geometric objective methods in the other two centers. OAR auto-segmentation accuracy was also graded by our subjective evaluation standard. These grading results were compared with those of DSC. Based on the subjective evaluation standard and the five geometric indexes, the correspondence between the subjective evaluation level and the geometric index range was established for each OAR.

RESULTS

For ΔCMD, ΔV, and MHD, the grading results of the geometric objective evaluation methods at our center and the other two centers were inconsistent. For DSC and AHD, the grading results of three centers were consistent. Seven OARs' grading results in the subjective evaluation standard were inconsistent with those of DSC. Six OARs' grading results in the subjective evaluation standard were consistent with those of DSC. Finally, we proposed a new evaluation method that combined the subjective evaluation level of those OARs with the range of corresponding DSC to determine the grading standard. If the DSC ranges between the adjacent levels did not overlap, the DSC range was used as the grading standard. Otherwise, the mean value of DSC was used as the grading standard.

CONCLUSIONS

A novel OAR-specific SOC grading standard in thorax was developed. The SOC grading standard provides a possible alternative for evaluation of the auto-segmentation accuracy for thoracic OARs.

摘要

背景

为了开发一种新的用于胸部每个危及器官(OAR)自动分割的主观-客观-综合(SOC)分级标准。

方法

一位放射肿瘤学家从 40 名患者的 CT 图像手动勾画了 13 个胸部 OAR。使用五个几何客观指标评估 OAR 自动分割的准确性,包括 Dice 相似系数(DSC)、质心之间的欧几里得距离差(ΔCMD)、体积差(ΔV)、最大 Hausdorff 距离(MHD)和平均 Hausdorff 距离(AHD)。将分级结果与另外两个中心的相应几何指标的几何客观方法的分级结果进行比较。还使用我们的主观评估标准对 OAR 自动分割的准确性进行分级。这些分级结果与 DSC 的分级结果进行了比较。基于主观评估标准和五个几何指标,为每个 OAR 建立了主观评估水平与几何指标范围之间的对应关系。

结果

对于 ΔCMD、ΔV 和 MHD,我们中心和另外两个中心的几何客观评估方法的分级结果不一致。对于 DSC 和 AHD,三个中心的分级结果一致。七个 OAR 的主观评估标准的分级结果与 DSC 的分级结果不一致。六个 OAR 的主观评估标准的分级结果与 DSC 的分级结果一致。最后,我们提出了一种新的评估方法,该方法将这些 OAR 的主观评估水平与相应 DSC 的范围相结合,以确定分级标准。如果相邻级别之间的 DSC 范围没有重叠,则使用 DSC 范围作为分级标准。否则,使用 DSC 的平均值作为分级标准。

结论

开发了一种新的用于胸部 OAR 的特定于 OAR 的 SOC 分级标准。SOC 分级标准为评估胸部 OAR 的自动分割准确性提供了一种可能的替代方法。