Corneal biomechanical parameters in keratoconus eyes with abnormal elevation on the back corneal surface only versus both back and front surfaces.

机构信息

Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Health Promotion Research Center, Zahedan University of Medical Sciences, Zahedan, Iran.

出版信息

Sci Rep. 2021 Jun 7;11(1):11971. doi: 10.1038/s41598-021-91263-7.

Abstract

Corneal biomechanical parameters were compared in 100 keratoconus eyes with abnormal elevation on the back corneal surface only (group 1), versus both the back and front surfaces (group 2). Scheimpflug tomography with Pentacam HR, corneal biomechanical assessments using Corvis ST and Ocular Response Analyzer (ORA) and corneal epithelium thickness maps using anterior segment optical coherence tomography were assessed. There were no significant differences in the IOP measured using Corvis ST and ORA, age or sex between the two groups. Statistically significant differences were found in all corneal shape parameters and all new parameters of Corvis ST: corneal stiffness parameter at first applanation (SP-A1), integrated inverse radius (IR) and deformation amplitude ratio (DAR)) between groups (p < 0.001). The classic parameters of ORA including corneal hysteresis (CH) and corneal resistance factor (CRF) were about 1.00 mmHg higher in group 1 (p < 0.001). In conclusion, keratoconus eyes with abnormal elevation limited to the back corneal surface have lower grade, stiffer corneal biomechanical parameters and less asymmetric shape. This is consistent with progressive biomechanical weakening from the first detectable back surface elevation to manifestation on the front surface as the severity overwhelms the ability of the epithelium to compensate.

摘要

对仅后表面角膜异常隆起的 100 例圆锥角膜眼(组 1)与后表面和前表面均异常隆起的圆锥角膜眼(组 2)的角膜生物力学参数进行了比较。使用 Pentacam HR 行 Scheimpflug 断层成像,使用 Corvis ST 和 Ocular Response Analyzer(ORA)进行角膜生物力学评估,使用眼前节光学相干断层扫描评估角膜上皮厚度图。组间 Corvis ST 和 ORA 测量的眼压、年龄或性别无显著差异。组间角膜形态参数和 Corvis ST 的所有新参数均存在统计学差异:首次压平的角膜刚性参数(SP-A1)、综合逆半径(IR)和变形幅度比(DAR)(p < 0.001)。ORA 的经典参数角膜滞后(CH)和角膜阻力因子(CRF)在组 1 中约高 1.00 mmHg(p < 0.001)。结论:局限于后表面的角膜异常隆起的圆锥角膜眼具有较低等级、更硬的角膜生物力学参数和较少的不对称性形态。这与从前表面首次检测到的后表面隆起开始的渐进性生物力学减弱一致,因为严重程度超过了上皮的代偿能力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4a0b/8184812/f96e6dafcaae/41598_2021_91263_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验