Abstract

Administering nitrite has therapeutic effects on ischemic conditions wherein the enzymatic production of nitric oxide depends on oxygen. We developed a supplemental fluid containing nitric oxide (NO) and determined the clearance and supply between the pre- and post-dilution modes of continuous hemofiltration in vitro. Nitric oxide gas, 1000 mL or 2000 mL, at a concentration of 1000 ppm, was injected into 2020 mL of conventional supplemental fluid (experimental solution). The same volume of nitrogen gas was injected into the supplemental fluid (control solution). NO concentrations were measured using commercially available NO assay kit. Pre- or post-dilution continuous hemofiltration was performed using a control solution as supplemental fluid to determine the NO clearance. We determined the NO concentration of the outlet blood circuit to confirm the NO supply using the experimental solution as supplemental fluid. Also, using the bovine blood, white blood cell and platelet change rates and the dialysis membrane water flux during continuous hemodiafiltration were evaluated ex vivo as index of the biocompatibilities of a nitric oxide-containing solution. NO was not detected in the control solutions. The experimental solutions significantly increased in nitric oxide concentrations. NO clearance increased as the increase in supplemental and ultrafiltration flow rates using the control solution as supplemental fluid. However, using the experimental solution as supplemental fluid, nitric oxide supply showed a similar trend of NO clearance. Without any changes in biocompatibility using the supplemental fluid containing NO, it could maintain intravascular nitric oxide during continuous renal replacement therapy.

摘要

给缺血性疾病患者施用亚硝酸盐具有治疗效果,因为一氧化氮的酶促产生依赖于氧气。我们开发了一种含有一氧化氮 (NO) 的补充液,并确定了体外连续血液滤过中预稀释和后稀释模式之间的清除率和供应。将浓度为 1000 ppm 的 1000 毫升或 2000 毫升一氧化氮气体注入 2020 毫升常规补充液(实验溶液)中。将相同体积的氮气注入补充液(对照溶液)中。使用市售的 NO 测定试剂盒测量 NO 浓度。使用对照溶液作为补充液进行预稀释或后稀释连续血液滤过,以确定 NO 清除率。我们使用实验溶液作为补充液确定出口血液回路中的 NO 浓度,以确认 NO 供应。此外,使用牛血液、白细胞和血小板变化率以及连续血液透析滤过过程中的透析膜水通量作为含有一氧化氮溶液的生物相容性的指标进行了离体评估。对照溶液中未检测到 NO。实验溶液中的一氧化氮浓度显著增加。使用对照溶液作为补充液时,随着补充和超滤流速的增加,NO 清除率增加。然而,使用实验溶液作为补充液时,NO 供应显示出与 NO 清除率相似的趋势。使用含有 NO 的补充液不会改变生物相容性,可以在连续肾脏替代治疗期间维持血管内一氧化氮。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验