Suppr超能文献

使用具有不同佩戴压力的柔性矫形器对健康年轻成年人进行膝关节角度传感。

Knee joint angle sensing in healthy young adults using flexible orthosis with different wearing pressure.

作者信息

Yamamoto Hiroaki, Wada Chikamune

机构信息

Department of Physical Therapy, Fukuoka Tenjin Medical Rehabilitation Academy: 4-3-7 Watanabedori, Chuo-ku, Fukuoka-shi, Fukuoka 810-0004, Japan.

Department of Life Science and System Engineering, Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Japan.

出版信息

J Phys Ther Sci. 2021 Jul;33(7):537-539. doi: 10.1589/jpts.33.537. Epub 2021 Jul 1.

Abstract

[Purpose] To investigate the effects of a flexible brace, by analyzing whether its usage; the difference in wearing pressure could change the joint position sensation in healthy participants; and develop a flexible knee brace for patients with knee osteoarthritis. [Participants and Methods] The study included eight healthy males with 14 knee joints (mean age, 22.0 ± 3.1 years). To measure joint position sense, an "angle reproduction test" was performed in three experimental conditions: 1) participants not wearing the brace, 2) the brace was secured with an appropriate force, and 3) the brace was fully secured using hook-and-loop fasteners. [Results] No significant difference was observed among groups comprising of those not wearing, those wearing with the standard force, and those wearing with the tight force. When the maximum hook-and-loop fastener was squeezed, the sensory error in joint position was maximized at both 30° and 60° flexion. [Conclusion] Joint position sense improvement was confirmed to be poor by orthosis, and an error occurred in the joint position sense by increasing the wearing pressure in orthosis. In future, measurements should be performed on patients with knee osteoarthritis who have decreased joint position sense and verify the effect of different wearing pressures verified.

摘要

[目的] 通过分析使用柔性支具的情况、佩戴压力差异是否会改变健康参与者的关节位置感觉,来研究柔性支具的效果,并为膝骨关节炎患者开发一种柔性膝关节支具。[参与者与方法] 该研究纳入了8名健康男性,共14个膝关节(平均年龄22.0±3.1岁)。为测量关节位置觉,在三种实验条件下进行了“角度再现测试”:1)参与者不佩戴支具;2)以适当力度固定支具;3)使用搭扣完全固定支具。[结果] 在不佩戴支具、以标准力度佩戴支具和以紧密力度佩戴支具的组间未观察到显著差异。当挤压最大搭扣时,在30°和60°屈曲时关节位置的感觉误差均最大。[结论] 证实矫形器对关节位置觉的改善作用不佳,且通过增加矫形器的佩戴压力会在关节位置觉上出现误差。未来,应对关节位置觉下降的膝骨关节炎患者进行测量,并验证不同佩戴压力的效果。

相似文献

3
Effects of knee orthoses on kinesthetic awareness and balance in healthy individuals.膝关节矫形器对健康个体本体感觉和平衡的影响。
J Rehabil Assist Technol Eng. 2019 Aug 5;6:2055668319852537. doi: 10.1177/2055668319852537. eCollection 2019 Jan-Dec.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。