Mayer C, Scharf D, Khoramnia R
Universitätsaugenklinik Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Deutschland.
Ophthalmologe. 2022 Feb;119(2):181-189. doi: 10.1007/s00347-021-01447-9. Epub 2021 Jul 8.
Three groups of iris prostheses can be distinguished for the surgical treatment of iris defects: (1) segmental iris implants, (2) combined iris diaphragm intraocular lenses (IOL) and (3) pure iris implants. Most iris reconstructions are accompanied by aphakia correction with secondary IOL implantation. Although the primary goal is to create a pupil and to improve glare perception, contrast sensitivity and visual acuity, the esthetic result is also a relevant component.
Functional and esthetic results after replacement of an aniridia IOL implant with a custom-made artificial iris with IOL.
In this retrospective study with seven eyes from seven patients, an iris diaphragm IOL (Morcher GmbH, Stuttgart, Germany) was exchanged for medical reasons (subluxation) against a custom-made artificial iris made of silicone (ArtificialIris, HumanOptics, Erlangen, Germany) in combination with a sutured IOL. The follow-up period was at least 3 months. Best corrected distance visual acuity (BCVA), endothelial cell count (ECC), complications, glare perception as well as esthetic outcome and patient satisfaction were evaluated.
The BCVA and ECC showed no statistically significant change between the preoperative and postoperative values (p > 0.05). There was a decentration of the iris IOL implant of 0.27 ± 0.19 mm three months postoperatively. On a visual analogue scale (VAS) from 1 to 10 (1 = not satisfied at all, 10 = extremely satisfied), satisfaction with the overall result was rated 8.6 ± 2.5. Subjective glare perception improved to 5.6 ± 3.5 and subjective esthetic impairment improved to 2.4 ± 2.0 on the VAS (1 = none, 10 = extremely strong). Postoperative complications included transient intraocular hypotonia in two eyes, intraocular pressure increase in two eyes, retinal detachment and transient vitreous hemorrhage in one eye each. Of the seven patients six would repeat the procedure.
Compared to a rigid aniridia IOL implant, replacement with a custom-made artificial iris in combination with an IOL provides not only a good functional result but simultaneously also an esthetically pleasing result.
在虹膜缺损的手术治疗中,可区分出三组虹膜假体:(1)节段性虹膜植入物;(2)带虹膜隔人工晶状体(IOL);(3)单纯虹膜植入物。大多数虹膜重建手术同时会植入二期人工晶状体以矫正无晶状体状态。虽然主要目标是形成瞳孔并改善眩光感知、对比敏感度和视力,但美学效果也是一个重要组成部分。
用定制的带人工晶状体的人工虹膜替换无虹膜人工晶状体植入物后的功能和美学效果。
在这项对7例患者的7只眼进行的回顾性研究中,因医学原因(晶状体半脱位)将虹膜隔人工晶状体(德国斯图加特的莫尔彻有限公司)替换为定制的由硅胶制成的人工虹膜(德国埃尔朗根的HumanOptics公司的ArtificialIris)并联合缝合人工晶状体。随访期至少3个月。评估最佳矫正远视力(BCVA)、内皮细胞计数(ECC)、并发症、眩光感知以及美学效果和患者满意度。
术前和术后的BCVA和ECC值无统计学显著变化(p>0.05)。术后3个月时虹膜人工晶状体植入物有0.27±0.19mm的偏心。在1至10分的视觉模拟量表(VAS)上(1=完全不满意,10=极其满意),对总体结果的满意度评分为8.6±2.5。主观眩光感知在VAS上改善至5.6±3.5,主观美学缺陷在VAS上改善至2.4±2.0(1=无,10=极其严重)。术后并发症包括2只眼出现短暂性眼内低眼压,2只眼眼压升高,1只眼发生视网膜脱离和1只眼出现短暂性玻璃体出血。7例患者中有6例愿意再次接受该手术。
与硬性无虹膜人工晶状体植入物相比,用定制的人工虹膜联合人工晶状体进行替换不仅能提供良好的功能效果,同时还能带来美观的效果。