利用光电容积脉搏波技术检测心脏病患者心跳的准确性。

The accuracy of heartbeat detection using photoplethysmography technology in cardiac patients.

机构信息

Department of Cardiology, Cardiology Centers of the Netherlands, Karel du Jardinstraat 61, Amsterdam, the Netherlands; Department of Vascular Medicine, Internal Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam Cardiovascular Sciences, Meibergdreef 9, Amsterdam, the Netherlands.

Department of Cardiology, Cardiology Centers of the Netherlands, Karel du Jardinstraat 61, Amsterdam, the Netherlands.

出版信息

J Electrocardiol. 2021 Jul-Aug;67:148-157. doi: 10.1016/j.jelectrocard.2021.06.009. Epub 2021 Jul 2.


DOI:10.1016/j.jelectrocard.2021.06.009
PMID:34256184
Abstract

INTRODUCTION: Photoplethysmography (PPG) in wearable sensors potentially plays an important role in accessible heart rhythm monitoring. We investigated the accuracy of a state-of-the-art bracelet (Corsano 287) for heartbeat detection in cardiac patients and evaluated the efficacy of a signal qualifier in identifying medically useful signals. METHODS: Patients from an outpatient cardiology clinic underwent a simultaneous resting ECG and PPG recording, which we compared to determine accuracy of the PPG sensor for detecting heartbeats within 100 and 50 ms of the ECG-detected heart beats and correlation and Limits of Agreement for heartrate (HR) and RR-intervals. We defined subgroups for skin type, hair density, age, BMI and gender and applied a previously described signal qualifier. RESULTS: In 180 patients 7914 ECG-, and 7880 (99%) PPG-heartbeats were recorded. The PPG-accuracy within 100 ms was 94.6% (95% CI 94.1-95.1) and 89.2% (95% CI 88.5-89.9) within 50 ms. Correlation was high for HR (R = 0.991 (95% CI 0.988-0.993), n = 180) and RR-intervals (R = 0.891 (95% CI 0.886-0.895), n = 7880). The 95% Limits of Agreement (LoA) were -3.89 to 3.77 (mean bias 0.06) beats per minute for HR and -173 to 171 (mean bias -1) for RR-intervals. Results were comparable across all subgroups. The signal qualifier led to a higher accuracy in a 100 ms range (98.2% (95% CI 97.9-98.5)) (n = 143). CONCLUSION: We showed that the Corsano 287 Bracelet with PPG-technology can determine HR and RR-intervals with high accuracy in cardiovascular at-risk patient population among different subgroups, especially with a signal quality indicator.

摘要

简介:可穿戴传感器中的光电容积脉搏波描记法(PPG)在可访问的心率监测中可能发挥着重要作用。我们研究了一种最先进的手镯(Corsano 287)在心脏病人群中检测心跳的准确性,并评估了信号质量指标在识别有医疗价值信号方面的效果。

方法:来自门诊心内科的患者接受了同步静息心电图和 PPG 记录,我们将其进行比较,以确定 PPG 传感器在检测心电图检测到的心跳 100 毫秒和 50 毫秒内的准确性,并评估心率(HR)和 RR 间隔的相关性和界限协议。我们根据皮肤类型、毛发密度、年龄、BMI 和性别定义了亚组,并应用了之前描述的信号质量指标。

结果:在 180 名患者中,记录了 7914 次心电图和 7880 次(99%)PPG 心跳。PPG 在 100 毫秒内的准确率为 94.6%(95%置信区间 94.1-95.1),在 50 毫秒内的准确率为 89.2%(95%置信区间 88.5-89.9)。HR(R = 0.991(95%置信区间 0.988-0.993),n = 180)和 RR 间隔(R = 0.891(95%置信区间 0.886-0.895),n = 7880)的相关性很高。HR 的 95%界限协议(LoA)为-3.89 至 3.77(平均偏差 0.06)次/分钟,RR 间隔的 LoA 为-173 至 171(平均偏差-1)次/分钟。结果在所有亚组中均具有可比性。信号质量指标在 100 毫秒范围内可提高准确率(98.2%(95%置信区间 97.9-98.5))(n = 143)。

结论:我们表明,Corsano 287 腕带与 PPG 技术相结合,可在不同亚组的心血管高危患者人群中以高精度确定 HR 和 RR 间隔,特别是使用信号质量指标时。

相似文献

[1]
The accuracy of heartbeat detection using photoplethysmography technology in cardiac patients.

J Electrocardiol. 2021

[2]
Continuous heart rhythm monitoring using mobile photoplethysmography in ambulatory patients.

J Electrocardiol. 2020

[3]
A Sliding Scale Signal Quality Metric of Photoplethysmography Applicable to Measuring Heart Rate across Clinical Contexts with Chest Mounting as a Case Study.

Sensors (Basel). 2023-3-24

[4]
Heart Rate Extraction from Novel Neck Photoplethysmography Signals.

Annu Int Conf IEEE Eng Med Biol Soc. 2019-7

[5]
Comparison of heart rate variability signal features derived from electrocardiography and photoplethysmography in healthy individuals.

Conf Proc IEEE Eng Med Biol Soc. 2006

[6]
Highly wearable cuff-less blood pressure and heart rate monitoring with single-arm electrocardiogram and photoplethysmogram signals.

Biomed Eng Online. 2017-2-6

[7]
Quantification of error between the heartbeat intervals measured form photoplethysmogram and electrocardiogram by synchronisation.

J Med Eng Technol. 2018-7

[8]
Validity of the Wrist-Worn Polar Vantage V2 to Measure Heart Rate and Heart Rate Variability at Rest.

Sensors (Basel). 2021-12-26

[9]
A Modified Mask for Continuous Cardiac Monitoring during Positive Airway Pressure Therapy.

Annu Int Conf IEEE Eng Med Biol Soc. 2018-7

[10]
Accuracy of continuous photoplethysmography-based 1 min mean heart rate assessment during atrial fibrillation.

Europace. 2023-3-30

引用本文的文献

[1]
Validation of nocturnal resting heart rate and heart rate variability in consumer wearables.

Physiol Rep. 2025-8

[2]
Selecting Wearable Devices to Measure Cardiovascular Functions in Community-Dwelling Adults: Application of a Practical Guide for Device Selection.

Mayo Clin Proc Digit Health. 2025-3-12

[3]
Continuous monitoring of critically ill patients using photoplethysmography-the road to a less invasive ICU monitoring.

Front Digit Health. 2025-5-30

[4]
Accuracy of smartwatches for measuring heart rate and oxygen saturation in cynomolgus macaques compared to clinical standards.

Lab Anim. 2025-8

[5]
Investigating the accuracy of Garmin PPG sensors on differing skin types based on the Fitzpatrick scale: cross-sectional comparison study.

Front Digit Health. 2025-3-27

[6]
Evaluation of In-Ear and Fingertip-Based Photoplethysmography Sensors for Measuring Cardiac Vagal Tone Relevant Heart Rate Variability Parameters.

Sensors (Basel). 2025-2-28

[7]
Diagnostic accuracy of ECG smart chest patches versus PPG smartwatches for atrial fibrillation detection: a systematic review and meta-analysis.

BMC Cardiovasc Disord. 2025-2-25

[8]
Performance of a medical smartband with photoplethysmography technology and artificial intelligence algorithm to detect atrial fibrillation.

Mhealth. 2025-1-14

[9]
Vital signs-based healthcare kiosks for screening chronic and infectious diseases: a systematic review.

Commun Med (Lond). 2025-1-21

[10]
Multicenter Evaluation of Machine-Learning Continuous Pulse Rate Algorithm on Wrist-Worn Device.

Digit Biomark. 2024-12-12

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索