Suppr超能文献

比较 Attune 膝关节系统和压配髁(PFC)Sigma 膝关节系统对全膝关节置换术患者中期功能恢复的影响。

Midterm functional recovery of Total knee arthroplasty patients compared between the ATTUNE knee system and the press fit condylar (PFC) SIGMA knee system.

机构信息

Department of Orthopedic Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, 2 Wanglang Road, Bangkoknoi, Bangkok, 10700, Thailand.

出版信息

BMC Musculoskelet Disord. 2021 Jul 13;22(1):620. doi: 10.1186/s12891-021-04464-6.

Abstract

BACKGROUND

The ATTUNE Knee System is a new prosthetic design that has theoretical advantages over the Press Fit Condylar (PFC) Sigma Knee System specific to improved knee kinematics and patellofemoral joint tracking. This study aimed to evaluate functional outcomes compared between the ATTUNE and PFC Sigma designs at a minimum follow-up of 5 years.

METHODS

We retrospectively reviewed data from total knee arthroplasty (TKA) patients who received either the ATTUNE or PFC Sigma system during November 2013 to February 2015 at Siriraj Hospital (Bangkok, Thailand). Functional outcomes were evaluated using Timed Up and Go (TUG) test, 2-min walk test (2MWT), modified knee score, numerical rating scale-pain, range of motion (ROM), and rate of anterior knee pain and crepitation at preoperation, 3-months, 1-year, and 5-years postoperatively.

RESULTS

Of 113 patients, 59 and 54 received the PFC Sigma and ATTUNE systems, respectively. At a minimum of 5-years follow-up, all functional outcomes improved significantly from the preoperative period although TUG test and 2MWT declined significantly from 1- to 5-years postoperatively only in the PFC Sigma group. The mean ROM at 5-years postoperatively was significantly higher in ATTUNE than in PFC Sigma; however, the difference was small (116° vs. 110°, respectively; p = 0.041). There were no significant differences in any of the other outcome measurements, including anterior knee pain, clunking, and crepitation, between groups at any study time point.

CONCLUSIONS

​Our results revealed no major differences in functional outcomes between the PFC Sigma and ATTUNE TKA designs at an intermediate-term follow-up of at least 5 years. Longer-term follow-up study is needed to evaluate the benefits of the ATTUNE design relative to polyethylene wear and the rate of aseptic loosening.

摘要

背景

ATTUNE 膝关节系统是一种新的假体设计,与 Press Fit Condylar(PFC)Sigma 膝关节系统相比,具有改善膝关节运动学和髌股关节跟踪的理论优势。本研究旨在评估 ATTUNE 和 PFC Sigma 设计之间的功能结果,随访时间至少为 5 年。

方法

我们回顾性地审查了 2013 年 11 月至 2015 年 2 月在泰国 Siriraj 医院接受 ATTUNE 或 PFC Sigma 系统的全膝关节置换术(TKA)患者的数据。使用计时起立行走测试(TUG)、2 分钟步行测试(2MWT)、改良膝关节评分、数字评分量表疼痛、关节活动度(ROM)、以及术前、术后 3 个月、1 年和 5 年的前膝疼痛和弹响率来评估功能结果。

结果

113 例患者中,59 例和 54 例分别接受了 PFC Sigma 和 ATTUNE 系统。在至少 5 年的随访中,所有功能结果均较术前显著改善,尽管仅在 PFC Sigma 组中,TUG 测试和 2MWT 在术后 1 年至 5 年显著下降。术后 5 年的平均 ROM 在 ATTUNE 组中明显高于 PFC Sigma 组;然而,差异较小(分别为 116°和 110°;p=0.041)。在任何研究时间点,两组之间在任何其他结果测量中,包括前膝疼痛、弹响和弹响,均无显著差异。

结论

在至少 5 年的中期随访中,我们的结果显示 PFC Sigma 和 ATTUNE TKA 设计在功能结果方面没有显著差异。需要进行更长时间的随访研究,以评估 ATTUNE 设计相对于聚乙烯磨损和无菌性松动的益处。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0e06/8278715/710d25a1a7eb/12891_2021_4464_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验