Abstract

BACKGROUND

The MiniBox+™ is an innovative technique for assessing lung volumes (LVs) and the diffusing capacity of the lung for carbon monoxide (DLco). Differently from the equipment needed for whole body plethysmography (WBP), the MiniBox+ is a small, transportable instrument, which derives total lung capacity (TLC) during tidal breathing by analyzing gas pressures and airflows immediately preceding and immediately following airway occlusions.

AIM

To compare the consistency and the feasibility of LV and DLco measurements between the two instruments in different lung function disorders, and their cost of execution.

METHODS

Consecutive patients of both genders with obstructive and restrictive respiratory disorders were randomly recruited. LVs and DLco were measured by a randomized sequence. The failure risk, number of attempts to achieve the first reliable measurement, corresponding time spent, and costs per patient were compared.

RESULTS

A total of 134 patients were enrolled: 42 asthmatics (32.1%), and 47 patients with obstructive (35.1%) and 44 with restrictive respiratory disorders (32.8%). The overall failure risk was 19.4% for WBP and 8.2% for the MiniBox+ (risk ratio=0.417, 95% CI 0.242 to 0.72). LVs and DLco values proved equal with both techniques, regardless of the patients' age, sex, schooling level, and initial lung disorder. Number of attempts and total time spent in achieving the first reliable measurement were significantly lower with the MiniBox+. Mean cost per patient was €87.58 with WBP and €75.11 with the MiniBox+, with a mean saving of €12.33 (95% CI 5.93 to 18.73), mainly due to the saving in productivity loss.

CONCLUSION

LV and DLco measurements with the MiniBox+ were highly consistent with those obtained with WBP. The MiniBox+ proved easier to use (lower failure risk) and more convenient (lower execution costs) than WBP.

摘要

背景

MiniBox+™是一种用于评估肺容积(LV)和肺一氧化碳弥散量(DLco)的创新技术。与全身体积描记法(WBP)所需的设备不同,MiniBox+是一种小型、可携带的仪器,它通过分析气道阻塞前后的气压和气流来推算潮气呼吸时的肺总量(TLC)。

目的

比较两种仪器在不同肺功能障碍中测量LV和DLco的一致性、可行性及其执行成本。

方法

连续招募患有阻塞性和限制性呼吸障碍的男女患者。通过随机顺序测量LV和DLco。比较失败风险、首次获得可靠测量的尝试次数、相应花费的时间以及每位患者的成本。

结果

共纳入134例患者:42例哮喘患者(32.1%),47例阻塞性呼吸障碍患者(35.1%),44例限制性呼吸障碍患者(32.8%)。WBP的总体失败风险为19.4%,MiniBox+为8.2%(风险比=0.417,95%可信区间0.242至0.72)。无论患者的年龄、性别、教育程度和初始肺部疾病如何,两种技术测得的LV和DLco值均相等。MiniBox+首次获得可靠测量的尝试次数和总时间显著更低。WBP每位患者的平均成本为87.58欧元,MiniBox+为75.11欧元,平均节省12.33欧元(95%可信区间5.93至18.73),主要是由于生产力损失的节省。

结论

MiniBox+测量LV和DLco与WBP高度一致。事实证明,MiniBox+比WBP更易于使用(失败风险更低)且更方便(执行成本更低)。