Suppr超能文献

基于二维磁共振成像和人体测量学指标预测青少年膝关节前交叉韧带重建术中使用的股四头肌腱-髌骨骨自体移植物的直径。

Prediction of quadriceps tendon-patellar bone autograft diameter in adolescents with 2-dimensional magnetic resonance imaging and anthropometric measures.

机构信息

Department of Orthopedics, Children's Hospital Colorado, 13123 E. 16th Avenue, Box 060, Aurora, CO, 80045, USA.

Department of Radiology, Children's Hospital Colorado, Aurora, CO, USA.

出版信息

Skeletal Radiol. 2022 Mar;51(3):619-623. doi: 10.1007/s00256-021-03874-w. Epub 2021 Jul 22.

Abstract

OBJECTIVES

This study evaluates the correlation between the bone end and soft tissue end of the quadriceps tendon-patellar bone autograft (QPA) size and pre-operative MRI measurements of the quadriceps tendon along sections to be included in the graft harvest in adolescents. We also assessed association between graft diameter and anthropometric measures (height, weight, and BMI), age, and sex.

METHODS

Patients (10-18 years) who underwent QPA ACL reconstruction and had a pre-operative MRI were considered for inclusion. Age, height, and weight, tibial and femoral side graft diameter, and patellar bone block dimensions were collected. Using a pre-operative 2D sagittal plane MRI, we measured the quadriceps at 10-mm increments above the patella, up to 40 mm. We assessed correlation between the bone-end graft diameter and the AP measure at 10 mm above the patella, and correlation between the soft-tissue end graft diameter and the most proximal AP measure.

RESULTS

A total of 103 patients were included. A significant correlation between the soft-tissue side graft diameter and most proximal AP measurement was observed (r = 0.51; p < 0.001). However, measurements significantly underestimated the soft-tissue end graft diameter (9.6 ± 0.8 vs. 7.4 ± 1.1; p < 0.001). There was no correlation between the bone-end graft diameter and AP measurement 10 mm above the patella. Anthropometric measures were not associated with graft size. Skeletal maturity was associated with smaller graft size (p = 0.08).

CONCLUSION

Soft-tissue end graft diameter is associated with the AP measure of the quadriceps at 20-40 mm above the superior pole of the patella.

摘要

目的

本研究评估了青少年膝关节前交叉韧带重建术中取自体股四头肌腱-髌骨骨(QPA)的骨端和软组织端与术中需截取的股四头肌腱术前 MRI 测量值之间的相关性。我们还评估了移植物直径与身高、体重、BMI、年龄和性别之间的关系。

方法

纳入行 QPA 前交叉韧带重建术且术前有 MRI 的患者。收集年龄、身高、体重、胫骨侧和股骨侧移植物直径、髌骨骨块尺寸。使用术前 2D 矢状面 MRI,我们在髌骨上方 10mm 处测量股四头肌,向上测量 40mm。我们评估了骨端移植物直径与髌骨上方 10mm 处的 AP 测量值之间的相关性,以及软组织端移植物直径与最接近的 AP 测量值之间的相关性。

结果

共纳入 103 例患者。软组织侧移植物直径与最接近的 AP 测量值之间存在显著相关性(r=0.51;p<0.001)。然而,测量值明显低估了软组织端移植物直径(9.6±0.8 比 7.4±1.1;p<0.001)。骨端移植物直径与髌骨上方 10mm 处的 AP 测量值之间无相关性。身高、体重、BMI 与移植物大小无关。骨骼成熟度与较小的移植物大小相关(p=0.08)。

结论

软组织端移植物直径与髌骨上极上方 20-40mm 处股四头肌的 AP 测量值相关。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验