Suppr超能文献

股四头肌肌腱自体移植物直径通常超过8mm,对于这种移植物类型,前交叉韧带重建术前可能无需进行尺寸估计:一项系统评价。

Quadriceps tendon autograft diameters are routinely above 8 mm, and preoperative size estimation before anterior cruciate ligament reconstruction may not be necessary for this graft type: A systematic review.

作者信息

Dworsky-Fried Joshua, Hadwen Amanda, Bernardini Luca, Vivekanantha Prushoth, Grassi Alberto, Ollivier Matthieu, de Sa Darren

机构信息

Michael DeGroote School of Medicine, McMaster University, Hamilton, Ontario, Canada.

School of Graduate Studies, Faculty of Health Sciences, McMaster University, Hamilton, Ontario, Canada.

出版信息

Knee Surg Sports Traumatol Arthrosc. 2025 Sep;33(9):3111-3133. doi: 10.1002/ksa.12558. Epub 2024 Dec 17.

Abstract

PURPOSE

To identify values of reported quadriceps tendon (QT) autograft diameter and length in anterior cruciate ligament reconstruction (ACLR), and to identify methods to predict these parameters.

METHODS

A search was conducted across three databases from inception to 30 March 2024. Data on study characteristics, demographics, anthropometric data, imaging techniques, and QT autograft or harvested QT tendon parameters were extracted. Values quantifying the statistical strength of associations between imaging or anthropometric characteristics and graft or tendon parameters as well as for associations between these parameters and postoperative outcomes were recorded.

RESULTS

A total of 3633 patients were included. The weighted mean QT autograft diameter and length were 8.9 (standard deviation [SD]: 0.7, range: 7.8-10.4) mm and 8.1 (SD: 1.3, range: 5.6-9.3) cm, respectively. A total of 93.8% of studies that reported mean QT autograft diameter found a value of 8 mm or greater. The QT groups had similar or significantly greater mean autograft diameter compared to the hamstring tendon (HT) groups in 91.7% of studies that reported significance. Regarding MRI measurements, 71.4% of the correlation coefficients reported showed a moderate positive correlation, 28.6% showed a low positive correlation and 14.3% showed a high positive correlation. Regarding anthropometric characteristics, 33.3% and 16.7%, 16.7% and 14.3% of studies that reported on the relationship between QT autograft diameter and height, weight, body mass index or age, respectively, found a low positive statistically significant correlation. Only statistically nonsignificant associations were reported between QT autograft parameters and post-operative outcomes and complications.

CONCLUSIONS

QT autografts used in ACLR have a mean diameter of 8 mm or greater and are consistently larger than HT autografts. Preoperative MRI measurements are better than anthropometric characteristics at predicting QT autograft parameters; however, preoperative prediction may not be necessary for this graft type. QT autograft parameters were not found to be significantly associated with any post-operative complication or outcome.

LEVEL OF EVIDENCE

Level IV.

摘要

目的

确定前交叉韧带重建(ACLR)中报告的股四头肌肌腱(QT)自体移植物直径和长度的值,并确定预测这些参数的方法。

方法

从数据库创建至2024年3月30日在三个数据库中进行检索。提取有关研究特征、人口统计学、人体测量数据、成像技术以及QT自体移植物或采集的QT肌腱参数的数据。记录量化成像或人体测量特征与移植物或肌腱参数之间关联的统计强度的值,以及这些参数与术后结果之间关联的统计强度的值。

结果

共纳入3633例患者。QT自体移植物直径和长度的加权平均值分别为8.9(标准差[SD]:0.7,范围:7.8 - 10.4)mm和8.1(SD:1.3,范围:5.6 - 9.3)cm。报告QT自体移植物平均直径的研究中,共有93.8%发现其值为8mm或更大。在报告有显著性差异的研究中,91.7%的QT组自体移植物平均直径与腘绳肌腱(HT)组相似或显著更大。关于MRI测量,报告的相关系数中,71.4%显示中度正相关,28.6%显示低度正相关,14.3%显示高度正相关。关于人体测量特征,分别报告QT自体移植物直径与身高、体重、体重指数或年龄之间关系的研究中,33.3%、16.7%、16.7%和14.3%发现有低度正相关且具有统计学显著性。仅报告了QT自体移植物参数与术后结果及并发症之间无统计学显著性的关联。

结论

ACLR中使用的QT自体移植物平均直径为8mm或更大,且始终大于HT自体移植物。术前MRI测量在预测QT自体移植物参数方面优于人体测量特征;然而,对于这种移植物类型,术前预测可能并非必要。未发现QT自体移植物参数与任何术后并发症或结果有显著关联。

证据级别

四级。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3b95/12392381/bed9edd5f4a8/KSA-33-3111-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验