To analyze the characteristics of patients with noise-induced hearing loss (NIHL) by comparing audiologic test findings between groups with and without tinnitus.
This study involved patients with noise-induced hearing loss (NIHL) who presented to the otolaryngology clinic between January 2016 and April 2019. Tests including 3 pure-tone audiometry (PTA) tests at intervals greater than 1 week, and auditory brainstem response (ABR) were evaluated and patients were screened for tinnitus. The tinnitus patients had otoacoustic emission. Comparison was done between the tinnitus group and the group without tinnitus.
Of the 730 subjects with NIHL, 389 had tinnitus. PTA showed significantly higher thresholds at 2 kHz to 8 kHz in the tinnitus group. Although ABR tests tended to show more prolonged I, III, and V latency in the tinnitus group, the differences were not statistically significant. Distortion product otoacoustic emissions (DPOAE) showed more abnormalities at 3 kHz, and 4 kHz than at 1 kHz and 2 kHz. Transient otoacoustic emission (TEOAE) showed abnormal findings in both ears.
In NIHL, hearing loss was more severe in patients with, than without tinnitus. DPOAE showed more abnormalities at 3 kHz, 4 kHz, and 6 kHz than at 1 kHz and 2 kHz, and TEOAE was abnormal at all frequencies.
通过比较有耳鸣和无耳鸣组的听力学检查结果,分析噪声性听力损失(NIHL)患者的特点。
本研究纳入了 2016 年 1 月至 2019 年 4 月在耳鼻喉科诊所就诊的噪声性听力损失(NIHL)患者。检查包括 3 次纯音听阈测试(PTA),间隔超过 1 周,以及听性脑干反应(ABR)测试,并对耳鸣患者进行耳鸣筛查。有耳鸣的患者行耳声发射检查。比较耳鸣组和无耳鸣组。
730 例 NIHL 患者中,389 例有耳鸣。PTA 显示耳鸣组在 2 kHz 至 8 kHz 频段的阈值显著升高。尽管 ABR 测试在耳鸣组中倾向于显示 I、III 和 V 潜伏期延长,但差异无统计学意义。畸变产物耳声发射(DPOAE)在 3 kHz 和 4 kHz 时比在 1 kHz 和 2 kHz 时异常更多,瞬态耳声发射(TEOAE)在双耳均有异常发现。
在 NIHL 中,有耳鸣的患者听力损失比无耳鸣的患者更严重。DPOAE 在 3 kHz、4 kHz 和 6 kHz 时异常更多,而在 1 kHz 和 2 kHz 时异常较少,TEOAE 在所有频率均异常。