Abstract

OBJECTIVES

Acoustic stapedius reflex threshold (ART) tests are included in a standard clinical acoustic immittance test battery as an objective cross-check with behavioral results and to help identify site of lesion. In traditional clinical test batteries, middle-ear admittance of a 226 Hz probe is estimated using ear-canal measurements in the presence of a reflex-activating stimulus. In the wideband (WB) acoustic immittance ART test used in this study, the pure-tone probe is replaced by a WB probe stimulus and changes in absorbed power are estimated using ear-canal measurements in the presence of the activator. The ART is defined as the lowest level at which a criterion change in admittance (clinical) or absorbed power (WB) is observed in the presence of the activator. In the present study, ARTs were obtained in adults with normal hearing using the clinical, manual method and with a new WB automated adaptive threshold detection method. It was hypothesized that the WB test would result in lower ARTs than the clinical test because reflex-related changes in power absorbance could be observed across multiple frequency bands in the WB test compared with a single frequency in the traditional test.

DESIGN

Data were collected in a prospective research design. ARTs were obtained in ipsilateral and contralateral conditions using 500, 1000, 2000 Hz, and broadband noise (BBN) activators on a clinical system and on an experimental WB system. The bandwidth of the BBN activator was 125 to 4000 Hz on the clinical system and 200 to 8000 Hz on the wideband system. ARTs were estimated at both tympanometric peak pressure (TPP) and ambient pressure on the WB system. Data were collected in both ears of 39 adults (21 males) of mean age 47.7 years (range 23-72 years). Differences in ARTs among the three threshold estimation methods (clinical, WB at TPP, WB at ambient) were examined using the general linear model repeated measures test in SPSS. Post-hoc pairwise comparisons were completed with Bonferroni correction for multiple comparisons. Statistical significance was defined as p < 0.05 for all analyses.

RESULTS

ARTs obtained on the WB system at TPP and ambient pressure were significantly lower than obtained on the clinical system. ARTs obtained on the WB system at TPP were significantly higher than at ambient pressure in the 500 and 2000 Hz ipsilateral conditions.

CONCLUSIONS

WB automated adaptive ARTs in normal-hearing adults were lower than for clinical methods when measured at TPP and ambient pressure. Lower presentation levels required to estimate ART in the WB test may be more tolerable to patients. Patients with ARTs that are not present at the maximum level of a traditional reflex test may have present ARTs with a WB ART test, which may reduce the need to refer for additional testing for possible retrocochlear involvement. Automation of the test may allow clinicians more time to attend to the other requisite tasks of a hearing evaluation and make the system useful for telehealth applications.

摘要

目的

声顺镫骨肌反射阈(ART)测试被包含在标准临床声导抗测试中,作为与行为结果的客观交叉检查,以帮助识别病变部位。在传统的临床测试电池中,使用耳腔测量值在反射激活刺激下估计 226 Hz 探头的中耳导纳。在本研究中使用的宽带(WB)声导抗 ART 测试中,用 WB 探头刺激物代替纯音探头,并且使用耳腔测量值在激活剂存在下估计吸收功率的变化。ART 定义为在激活剂存在下观察到导纳(临床)或吸收功率(WB)的标准变化时的最低水平。在本研究中,使用临床手动方法和新的 WB 自动自适应阈值检测方法在听力正常的成年人中获得了 ARTs。假设 WB 测试会导致比临床测试更低的 ARTs,因为与反射相关的吸收功率变化可以在 WB 测试中观察到多个频带,而在传统测试中只有一个频率。

设计

数据是在前瞻性研究设计中收集的。在临床系统和实验性 WB 系统上使用 500、1000、2000 Hz 和宽带噪声(BBN)激活器,在同侧和对侧条件下获得 ARTs。BBN 激活器的带宽在临床系统上为 125 至 4000 Hz,在宽带系统上为 200 至 8000 Hz。在 WB 系统上,在鼓室压峰值(TPP)和环境压力下均估算 ARTs。在平均年龄为 47.7 岁(23-72 岁)的 39 名成年人(21 名男性)的双耳中收集数据。使用 SPSS 中的一般线性模型重复测量检验检验三种阈值估计方法(临床、TPP 处的 WB、环境压力处的 WB)之间的 ARTs 差异。使用 Bonferroni 校正进行多次比较完成事后两两比较。所有分析的统计显著性定义为 p < 0.05。

结果

在 TPP 和环境压力下在 WB 系统上获得的 ARTs 明显低于在临床系统上获得的 ARTs。在同侧 500 和 2000 Hz 条件下,在 TPP 处获得的 WB 系统上的 ARTs 明显高于在环境压力下获得的 ARTs。

结论

当在 TPP 和环境压力下测量时,正常听力成年人的 WB 自动自适应 ARTs 低于临床方法。在 WB 测试中估计 ART 所需的较低呈现水平可能对患者更耐受。ART 不在传统反射测试的最大水平的患者可能具有存在的 ART 与 WB ART 测试,这可能减少对可能的耳蜗后参与的进一步测试的需要。测试的自动化可能使临床医生有更多时间关注听力评估的其他必要任务,并使该系统可用于远程医疗应用。

相似文献

8
Acoustic reflex measurement.声反射测量。
Ear Hear. 2013 Jul;34 Suppl 1:43S-47S. doi: 10.1097/AUD.0b013e31829c70d9.

引用本文的文献

3
Wideband Acoustic Reflex Measurement.宽带声反射测量
Semin Hear. 2023 Mar 14;44(1):84-92. doi: 10.1055/s-0043-1763296. eCollection 2023 Feb.
4
The Rise and Fall of Aural Acoustic Immittance Assessment Tools.耳声导抗评估工具的兴衰
Semin Hear. 2023 Mar 14;44(1):5-16. doi: 10.1055/s-0043-1764139. eCollection 2023 Feb.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验