Schairer Kim S, Ellison John C, Fitzpatrick Denis, Keefe Douglas H
Center for Hearing Research, Boys Town National Research Hospital, 555 N. 30th Street Omaha, Nebraska 68131, USA.
J Acoust Soc Am. 2007 Jun;121(6):3607-16. doi: 10.1121/1.2722213.
The goals of the current study were to: 1) evaluate the feasibility of a new wideband approach to measuring middle-ear muscle reflex (MEMR) status, and 2) to test the hypothesis that ipsilateral thresholds elicited with 1 or 2 kHz tones and broadband noise activators on a wideband acoustic transfer function (WATF) system are lower than thresholds elicited on a clinical system. Clinical MEMR tests have limitations, including the need for high activator levels to elicit a shift in a narrowband probe (e.g., a 0.226 or 1 kHz tone). Wideband MEMR tests using WATFs may elicit the reflex at lower levels because a wideband probe (click) is used and the threshold detection criterion can be wideband. Mean wideband MEMR thresholds across 40 normal-hearing adult ears were 2.2-4.0 dB lower than clinical MEMR thresholds, depending on the activator and specific WATF test used (admittance magnitude or energy reflectance). Wideband MEMR has potential clinical utility beyond the adult population, including use in newborn and preschool hearing screenings. In a newborn hearing screening, for example, wideband MEMR could be completed with the same system as otoacoustic emissions. However, further investigations in infants and young children are needed.
1)评估一种测量中耳肌肉反射(MEMR)状态的新型宽带方法的可行性,以及2)检验以下假设:在宽带声学传递函数(WATF)系统上,使用1或2 kHz纯音和宽带噪声激活器引出的同侧阈值低于在临床系统上引出的阈值。临床MEMR测试存在局限性,包括需要高激活水平才能在窄带探头(例如0.226或1 kHz纯音)上引出偏移。使用WATF的宽带MEMR测试可能会在较低水平引出反射,因为使用了宽带探头(咔嗒声),并且阈值检测标准可以是宽带的。根据所使用的激活器和特定的WATF测试(导纳幅值或能量反射率),40只正常听力成年耳朵的平均宽带MEMR阈值比临床MEMR阈值低2.2 - 4.0 dB。宽带MEMR在成年人群之外具有潜在的临床应用价值,包括用于新生儿和学龄前儿童听力筛查。例如,在新生儿听力筛查中,宽带MEMR可以使用与耳声发射相同的系统完成。然而,需要对婴幼儿进行进一步研究。