Gracia R, Busquets M, Gil M, Cortés A, Bozal J
Departament de Bioquímica i Fisiologia, Facultat de Química, Universitat de Barcelona, Spain.
J Biochem Biophys Methods. 1987 Nov;15(2):63-9. doi: 10.1016/0165-022x(87)90034-0.
A spectrophotometric assay is proposed to determine the levels of aspartate aminotransferase (AAT) isoenzymes from chicken liver by a steady-state kinetic method which depends on the differential inhibition of these isoenzyme forms by high concentrations of substrate 2-oxoglutarate at pH 6.2. The use of a standard curve permits the determination of the percentage of chicken liver c-AAT and m-AAT isoenzymes. This method yields results in good correlation with those achieved by different extent adipate inhibition and by differential centrifugation.