支架设计对支架内再狭窄和主要心脏结局的影响:一项范围综述和荟萃分析。

Influences of Stent Design on In-Stent Restenosis and Major Cardiac Outcomes: A Scoping Review and Meta-Analysis.

作者信息

Istanbullu Omer Burak, Akdogan Gulsen

机构信息

Department of Biomedical Engineering, Faculty of Engineering, Erciyes University, Kayseri, Turkey.

出版信息

Cardiovasc Eng Technol. 2022 Feb;13(1):147-169. doi: 10.1007/s13239-021-00569-0. Epub 2021 Aug 18.

Abstract

Thanks to the developments in implantable biomaterial technologies, invasive operating procedures, and widespread applications especially in vascular disease treatment, a milestone for interventional surgery was achieved with the introduction of vascular stents. Despite vascular stents providing a solution for embolisms, this technology includes various challenges, such as mechanical, electro-chemical complications, or in-stent restenosis (ISR) risks with long-term usage. Therefore, further development of biomaterial technologies is vital to overcome such risks and problems. For this purpose, recent research has focused mainly on the applications of surface modification techniques on biomaterials and vascular stents to increase their hemocompatibility. ISR risk has been reduced with the development and prevalent usage of the art technology stent designs of drug-eluting and biodegradable stents. Nevertheless, their problems have not been overcome completely. Furthermore, patients using drug-eluting stents are faced with further clinical challenges. Therefore, the bare metal stent, which is the first form of the vascular stent technology and includes the highest ISR risk, is still in common usage for vascular treatment applications. For this reason, further research is necessary to solve the remaining vital problems. In this scoping review, stent-based major cardiac events including ISR are analyzed depending on different designs and material selection in stent manufacturing. Recent and novel approaches to overcome such challenges are stated in detail.

摘要

得益于可植入生物材料技术、侵入性手术程序的发展,尤其是在血管疾病治疗中的广泛应用,血管支架的引入实现了介入手术的一个里程碑。尽管血管支架为栓塞提供了一种解决方案,但这项技术存在各种挑战,如机械、电化学并发症,或长期使用时的支架内再狭窄(ISR)风险。因此,生物材料技术的进一步发展对于克服此类风险和问题至关重要。为此,近期的研究主要集中在生物材料和血管支架表面改性技术的应用上,以提高它们的血液相容性。随着药物洗脱支架和可生物降解支架等先进技术支架设计的发展和广泛使用,ISR风险有所降低。然而,它们的问题尚未得到完全解决。此外,使用药物洗脱支架的患者还面临着进一步的临床挑战。因此,作为血管支架技术的第一种形式且ISR风险最高的裸金属支架,仍在血管治疗应用中普遍使用。因此,有必要进行进一步研究以解决其余的关键问题。在本范围综述中,根据支架制造中的不同设计和材料选择,分析了包括ISR在内的基于支架的主要心脏事件。详细阐述了克服此类挑战的最新和新颖方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验